TRACERLINE COBRA-Plus TP-935036 Manual De Instrucciones

Enlaces rápidos

1
6
7
English
1. Adjustable eyepiece
2. Housing
3. Battery door
4. Shaft
5. Distal tip
6. On/off switch
7. Battery compartment
8. Inspection mirror
French
1. Oculaire
2. Boîtier
3. Porte du compartiment à piles
4. Tuyau
5. Embout distal
6. Interrupteur marche-arrêt
(On/Off)
7. Compartiment à piles
8. Mirroir d'inspection
Spanish
1. Anteojo ajustable
2. Cubierta
3. Puerta de Pila
4. Eje
2
3
5
4
8
5. Extremidad distal
6. Interruptor encendido/apagado
(On/Off)
7. Compartimiento de Pilas
8. Espejo de Inspección
German
1. Justierbares Augenstück
2. Gehäuse
3. Batterie-gehäuse-abdeckung
4. Schaft
5. Distale Spitze
6. Ein-/Aus-Schalter
7. Batteriegehäuse
8. Inspektionsspiegel
Italian
1. Oculare regolabile
2. Involucro
3. Sportello batteria
4. Tubo flessibile
5. Punta distale
6. Interruttore acceso/spento
7. Compartimento batteria
8. Specchietto di ispezione
8/07
AM07020
PRINTED IN U.S.A.
English
COBRA-Plus™ TP-935036
Multi-Purpose Borescope
U.S. Pat. No. 6,491,408
Basic Specifications
Viewing angle –– 40 degrees
Viewing distance –– 0.4 in (1 cm) to infinity
Housing material –– Nylon 6
Bending diameter –– 3 in (7.6 cm) minimum
Tip diameter –– 0.4 in (10 mm) shaft
Shaft –– 36 in (91 cm)
Light sources –– One UV LED and one white light LED
Batteries –– The COBRA-Plus™ multi-purpose borescope is powered
by (4) AA alkaline batteries. The batteries are held within a removable
battery pack just beneath the battery door.
To replace batteries –– Remove the battery door with a Phillips screw-
driver. Tilt the pack up from the bottom of the handle and remove. Do
not put unnecessary strain on the wire leads and never pick up the
scope by the leads. Unclip the connector if required. Change out bat-
teries, reattach the connector and replace in reverse order.
Lighting –– The COBRA-Plus borescope is equipped with 2 service-
free, integrated solid-state LEDs (one UV and one white light). Press
the switch to the left for white light and to the right for UV. To turn off,
press the switch to the middle position.
NOTE: Please refer to "Cleaning and storage" for trouble-free service.
Eyepiece Focusing –– The eyepiece has been factory set to be in
focus and should need very little adjustment in the field. You should
only need to turn the eyepiece by several turns in either direction to be
in focus. If you feel resistance in adjustment, do not exert force but
reverse the direction. Continue until the image is in focus.
Inspection Mirror –– P/N 123775
The inspection mirror is intended for external use only. In some
cases, the mirror can be dislodged and not easily retrieved. The
user takes full responsibility in these instances. Accordingly, please
use good judgment when employing the mirror.
General Operation, Checks and Care
A. General borescope checks before and after each use
1. Before and after each use, check the COBRA-Plus
borescope for rips, tears and abrasions.
2. Check for proper operation of lighting. If dim or not lighting,
first replace the batteries.
3. Check for smooth rotation of the eyepiece.
B. Operation
1. Always exercise care when inserting and removing the shaft
of the borescope into and from the hole of the object you are
inspecting.
2. Try to predetermine the route and location of the area you
are inspecting. With this you can prebend the 10mm shaft in
the direction you require to facilitate viewing.
3. Never bend the shaft length tighter than 3 in (7.6 cm)
diameter.
4. Never expose the housing to water or liquids.
5. Never insert the shaft into hot locations greater than 158º F
(70º C).
6. Never use the borescope near moving parts such as gears,
fan blades or moving belts.
IMPORTANT
To properly position the inspection mirror, align and tilt the base
against the flat portion of the distal tip. Push it into place, making
sure that the clip is fully seated in the recessed section of the distal
tip.
CAUTION
loading

Resumen de contenidos para TRACERLINE COBRA-Plus TP-935036

  • Página 1 English COBRA-Plus™ TP-935036 Multi-Purpose Borescope U.S. Pat. No. 6,491,408 Basic Specifications Viewing angle –– 40 degrees Viewing distance –– 0.4 in (1 cm) to infinity Housing material –– Nylon 6 Bending diameter –– 3 in (7.6 cm) minimum Tip diameter –– 0.4 in (10 mm) shaft Shaft ––...
  • Página 2 êtes en in the case. train d'inspecter. If any problems occur with your COBRA-Plus TP-935036 borescope, 2. Essayez de pré-déterminer le parcours et l'endroit que vous do not attempt to open the housing.
  • Página 3 No ponga una tensión innecesaria Si tiene un problema con el endoscopio COBRA-Plus TP-935036 en los conductores de alambre y nunca levante la unidad tirando de no trate de abrir la cubierta.
  • Página 4 Tubo flessible –– 91 cm Fonti di illuminazione –– Un LED a UV ed un LED con luce bianca Se si incontrano problemi con l'endoscopio COBRA-Plus TP-935036, non tentare di aprire l'involucro. Batterie –– L'endoscopio multiusi COBRA-Plus™ TP-935036 è alimen- tato da (4) batterie alcaline AA.