Faults and fault rectification

Check any faults in the appliance against the following table:
Fault
The mains indi­
cator light does
not illuminate af­
ter switching on.
The appliance is
switched on but
does not heat
up.
If you cannot remedy the fault,
‒ switch off the appliance and disconnect from the mains,
‒ do not open the housing,
‒ contact the authorised Customer Service agent.
8.

Technical specifications

Grill-roaster
Item No.
Total connected load
Voltage
Fuse
Thermal output, sensitive
Thermal output, latent
Steam output
External dimensions (LxWxH)
Weight
Degree of protection against water
Appliance noise level
We reserve the right to make technical changes!
26 / 88
Possible cause
Main switch in building not
switched on before switching
on the appliance.
There is no power supply at
all.
Mains fuse on site has
tripped.
The safety temperature limiter
has tripped.
Action
Turn on main switch.
Inform the power supply company.
Possible faults on the appliance must
be checked by an authorised Customer
Service agent.
Reset the circuit breaker.
Possible faults on the appliance must
be checked by an authorised Customer
Service agent.
BC DG 4200
00574208
4.2 kW
400V 3 N 50/60Hz
3 x 16 A
1.38 kW
1.68 kW
2.47 kg/h
400 x 620 x 240 mm
approx. 33 kg
IP X4
< 70dB (A)
Tabla de contenido