Lanaform Breezy Cube Manual De Instrucciones página 8

Ocultar thumbs Ver también para Breezy Cube:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
REPLACING THE FILTER [ insert_p 5]
For optimum performance, replace the filter
every three months or after approximately
500 hours of use. When the filter reaches the
end of its serviceable life, the light below
the "Refill/Filter" flashes
[ insert_p 4 label 1]
Troubleshooting
The device is overflowing.
The device is not working
/ The fan is not turning
/ No light indicator.
The device does not cool
down / not sufficiently.
Unpleasant smell.
Unusual noise emitted
during operation.
Minerals accumulating
in the cooling device.
report_p The following effects are not
regarded as malfunctions:
1 If your water is particularly hard
(contains a lot of minerals), the
device may produce a sort of white
dust. This is not a malfunction. The
solution is to clean it more frequently
or to use water that is not as hard.
2 The device runs very calmly but not
entirely quietly. A sound level of less
than 53DB is regarded as normal.
ADVICE ON WASTE
DISPOSAL
The packaging consists entirely of envi-
ronmentally-friendly materials that can be
taken to your local waste sorting centre to
be used as secondary materials. Cardboard
can be placed in a paper collection contain-
8
English
/ 56
E-IM-BreezyCube-003-Version 2-3colonnes.indd 8
E-IM-BreezyCube-003-Version 2-3colonnes.indd 8
info_out If you live in a place where
the water is hard, it may need
to be changed more frequently.
In these cases, you will see
minerals accumulating on the
cooling device which might in
.
time obstruct the air flow.
Disconnect the air cooler.
Remove the air vent with the push-but-
ton at the top right of the vent.
Take out the used filter.
Cause
Cooler tank drain plug
in the wrong place.
Unstable surface
Cracked or damaged reservoir.
Adapter not powerful enough.
No voltage, no current.
Cable out of service.
Relative humidity too high /
ambient temperature too low.
Evaporation has
not yet started.
Empty reservoir / dry filter.
The air cooler is new.
The water is polluted or has
been in the reservoir too long.
The filter has stayed
damp for too long.
The device is on an unstable
or non-flat surface.
Using hard water.
er. Packing film must be taken to your local
sorting and recycling centre.
When you are no longer using the device,
dispose of it in an environmentally respon-
sible manner and in compliance with the
statutory requirements.
LIMITED WARRANTY
LANAFORM guarantees that this product
will be free from any material and work-
manship defects for a period of two years
from the date it was purchased, other than
as specified below.
The LANAFORM warranty does not cover
damage caused by normal wear and tear
on this product. In addition, the warranty
on this LANAFORM product does not cover
damage caused as a result of any abusive,
inappropriate or incorrect use, accident,
attachment of any unauthorised accesso-
Then insert the new filter, making sure
it is positioned correctly as on the dia-
gram, i.e. with the opening towards the
bottom and slot it in towards you.
Re-insert the air vent and connect the
device so that it can be used again.
TROUBLESHOOTING
[ label 1]
In the event of a malfunction under nor-
mal conditions of use, please refer to the
[ label 2]
following list:
[ label 3]
Solution
Replace the cooler tank drain plug so that it is tightly closed.
Place the device on a horizontal, stable, flat surface and
do not move the device if it still contains water.
Contact your supplier's after-sales service.
Use only the mains adaptor supplied with this device.
Check that the USB connector is securely attached
to the device; check whether the device is
connected and that there is no mains fault.
Use another USB cable (type B USB micro) or
contact your supplier's after-sales service.
The device cools down through evaporation (please see
chapter on "How does cooling work through evaporation"),
and may vary depending on the conditions.
Wait for a few minutes because evaporation takes a
little time before the freshness is noticeable.
Add water to the reservoir.
Drain the water from the reservoir and
leave it to air for at least 12 hours.
Unplug the device, drain the water from the
reservoir, rinse and clean the reservoir, and fill the
reservoir with demineralised or distilled water.
Rotate the fan without any water in the reservoir to dry the filter or
even remove the filter from the device and let it dry in the open air.
Unplug the device and place it on a flat, stable surface.
Clean the device and use distilled water.
ry, modification of the product or any oth-
er situation of whatever kind, beyond the
control of LANAFORM.
LANAFORM shall not be held liable for
any type of incidental, consequential or
special damage.
Any implied warranties of the product's
fitness for purpose are limited to a period
of two years from the original purchase
date on presentation of a copy of the proof
of purchase.
Upon receipt, LANAFORM will repair or
replace your device, as appropriate, and
return it to you. The warranty may only be
used at the LANAFORM Service Centre. Any
maintenance and repair work carried out
on this product by any person other than
the LANAFORM Service Centre will invali-
date this warranty.
[ label 4]
11-03-21 14:23:35
11-03-21 14:23:35
loading