Modbus
aerWeb300
address
address
(BMS 1)
(BMS2)
253
5046
254
5047
255
5048
256
5049
257
5050
258
5051
259
5052
260
5053
261
5054
262
5055
263
5056
264
5057
265
5058
266
5059
267
5060
268
5061
269
5062
270
5063
271
5064
272
5065
273
5066
274
5067
275
5068
276
5069
277
5070
278
5071
408
5201
409
5202
410
5203
411
5204
412
5205
413
5206
12
EN
BMS - pCO5 1309 5806600
Carel
add.
45
Upper part peak counter, circuit 1 CP1A
46
Lower part peak counter, circuit 1 CP1A
47
Upper part peak counter, circuit 1 CP1B
48
Lower part peak counter, circuit 1 CP1B
49
Upper part peak counter, circuit 2 CP1
50
Lower part peak counter, circuit 2 CP1
51
Upper part peak counter, circuit 2 CP1A
52
Lower part peak counter, circuit 2 CP1A
53
Upper part peak counter, circuit 2 CP1B
54
Lower part peak counter, circuit 2 CP1B
55
56
57
58
59
60
Code NRL - Size
61
Code NRL - Comp. Type
62
Code NRL - Valve
63
Code NRL - model
64
Code NRL - recovery
65
Code NRL - Version
66
Code NRL – Batteries
67
Code NRL – Fan
68
Code NRL - Supply
69
Code NRL - Storage
70
Unit range identification code (0=NRL)
200
Circ 1 power
201
Circ 2 power
Circuit 1 defrost state (0=DISABLED, 1=BYPASS,
3=CALCULATION OF DECAY, 11=CYCLE INVERSION STAND-BY,
202
13=DEFROST START, 14=DEFROST IN PROGRESS, 15=CYCLE
INVERSION STAND-BY, 17=DEFROST END, 20=FIRST DEFROST)
Circuit 1 defrost events (1=External high temperature,
2=Circuit off, 3=BP above minimum threshold, 4=Minimum
time between defrosts, 5=CP start, 6=new BP reference,
203
7=start to BP limit, 8=delta P start, 9=liquid temperature
OK, 10=Minimum defrost time, 11=another circuit stand-by,
12=bypass first start, 13=Low liquid temperature, 14=high
TGP start, 15=forced)
Circuit 2 defrost state (0=DISABLED, 1=BYPASS,
3=CALCULATION OF DECAY, 11=CYCLE INVERSION STAND-BY,
204
13=DEFROST START, 14=DEFROST IN PROGRESS, 15=CYCLE
INVERSION STAND-BY, 17=DEFROST END, 20=FIRST DEFROST)
Circuit 2 defrost events (1=External high temperature,
2=Circuit off, 3=BP above minimum threshold, 4=Minimum
time between defrosts, 5=CP start, 6=new BP reference,
205
7=start to BP limit, 8=delta P start, 9=liquid temperature
OK, 10=Minimum defrost time, 11=another circuit stand-by,
12=bypass first start, 13=Low liquid temperature, 14=high
TGP start, 15=forced)
Description
Unit of
meas-
Min
Max
urement
---
0
999
---
0
999
---
0
999
---
0
999
---
0
999
---
0
999
---
0
999
---
0
999
---
0
999
---
0
999
---
0
20
---
0
3
---
0
2
---
0
3
---
0
3
---
0
3
---
0
2
---
0
3
---
0
2
0
999
%
0
999
%
0
999
---
0
99
---
0
99
---
0
99
---
0
99
r/W
R
R
R
R
R
R
R
R
R
R
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R
R
R
R
R
loading