Levenhuk Ermenrich Verk LL60 Guia Del Usuario página 3

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 8
Ermenrich Verk LL60 Digital Level
EN
Please carefully read the safety instructions and the user manual before using this product. Keep away from children. Use the
device only as specified in the user manual.
Getting started
Open the battery compartment cover and insert 2 AAA batteries. Close the cover.
Press the POWER/BUZZER button to turn the device on. Press and hold the POWER/BUZZER button for 3 seconds to turn the device off.
The device will shut down in 3 minutes of no activity.
To measure, place the device on a flat surface.
Usage
When the device is on, it will display the current value in degrees. Press the MODE button to switch between °, %, mm/m, and in/ft. The
slope is shown in inches per foot in 1/8-in increments.
The
icon indicates either the horizontal or vertical position of the measured surface. The
that the measured surface deviates from the horizontal or vertical plane. The
adjusted horizontally or vertically.
Angle measurement. If you want to set an alternative reference point from which to take measurements, press the ZERO button to set
the value to 0. The S icon will appear on the screen. Press the ZERO button again to exit this function.
Hold function. To freeze the readings, press the HOLD button. The H icon will appear on the screen. Press HOLD button again to return to
measurement mode.
Acoustic alert. Press the POWER/BUZZER button. The
within +/-1° of the horizontal or vertical position, the frequency of the sound differs when the device is near or far from the horizontal or
vertical position, and alerts continuously when the device is in the horizontal or vertical position. Press the POWER/BUZZER button again
to turn this function off.
Calibration
Press the POWER/BUZZER button to turn the device off. Place the device on a flat surface. Press and hold the MODE button and then
press the POWER/BUZZER button until CAL1 appears on the display. Do not move the device and then press the MODE button. The icon
CAL1 will start flashing and then the CAL2 icon will appear on the display. Rotate the device 180° and then press the MODE button.
The CAL2 icon will start flashing. When CAL2 disappears, the calibration is complete. The calibration should be performed on a flat and
smooth surface with a slope not exceeding 5°. If it exceeds 5°, the display will show the Erro icon, indicating that the calibration cannot be
performed.
Specifications
Length
Resolution
Measuring range
Accuracy
Measurements
Auto-off
Operating temperature range
Storage temperature range
Power supply
The manufacturer reserves the right to make changes to the product range and specifications without prior notice.
Care and maintenance
Use the device only as specified in the user manual. Keep away from children. Do not try to disassemble the device on your own for any
reason. For repairs and cleaning of any kind, please contact your local specialized service center. Protect the device from sudden impact
and excessive mechanical force. Do not use the product in explosive environment, close to flammable materials. Store the device in a dry
cool place. Only use accessories and spare parts for this device that comply with the technical specifications. Never attempt to operate
a damaged device or a device with damaged electrical parts! If a part of the device or battery is swallowed, seek medical attention
immediately.
Battery safety instructions
Always purchase the correct size and grade of battery most suitable for the intended use. Always replace the whole set of batteries at one
time; taking care not to mix old and new ones, or batteries of different types. Clean the battery contacts and also those of the device prior
to battery installation. Make sure the batteries are installed correctly with regard to polarity (+ and –). Remove batteries from equipment
that is not to be used for an extended period of time. Remove used batteries promptly. Never short-circuit batteries as this may lead to high
temperatures, leakage, or explosion. Never heat batteries in order to revive them. Do not disassemble batteries. Remember to switch off
devices after use. Keep batteries out of the reach of children, to avoid risk of ingestion, suffocation, or poisoning. Utilize used batteries as
prescribed by your country's laws.
icon indicates whether the measured surface must be
icon will appear on the screen. The audible buzzer alerts when the device is
600mm
0.05°
0 to 360°
±0.1° at 0° and 90°, the rest: ±0.2°
°, %, mm/m, in/ft
3 min.
0...+40°C / 32...+104°F
–10...+50°C / 14...+122°F
2 alkaline AAA batteries