Vector Welding Paris 1000 Instrucciones De Operación página 21

Idiomas disponibles
  • ES

Idiomas disponibles

Summary
PLASMA CUTTING SERIES EQUIPMENT
2.1 Brief Introduction
Paris 500, Paris 700, Paris 1000 plasma cutting machines adopts the latest pulse width
modulation (PWM) technology and insulated gate bipolar transistor (IGBT) power module, which
can change work frequency to medium frequency so as to replace the traditional hulking work
frequency transformer with the cabinet medium frequency transformer. Thus, its characterized
with portable, small size, light weight, low consumption and etc.
Paris 500, Paris 700, Paris 1000 plasma cutting machines Characteristics:
◆IGBT technology.
◆With EMI filter to minimize the pollution of the electrified net.
±
◆High mains voltage tolerance
15%to maintain stable work.
◆MCU control system, responds immediately to any changes.
◆Excellent cutting capability.
◆Pilot arc controller, can cut grid workpiece.
◆Intelligent protection: over-current, over-heat, when the mentioned problems occoured,
the alarm lamp on the front panel will be on and the output current will be cut off. It can
self-protect and prolong the using life.
2.2 Specifications
Description
Pairs 500
7kg
Weight
Power source dimensions
365x160x380
Cooling
Fan cooled
Welder type
Inverter power source
European standards
EN 60974-1 / IEC 60974-1
1 x 230 Volt ±15%
Mains voltage
Grid frequency
50/60Hz
20-50 A
Cutting rurrent range
Effective input current
18.7A
Maximum input current
33.9A
Generator requirement
12.8KVA
50A@ 30%100V
Duty cycle, 40°C, 10 min
38.7A@ 60%95.5V
27.3A@ 100%91V
Open circuit voltage
266V DC
Schutzgrad
IP23
Protection class
H
Quality cutting thickness (500mm/min)
8mm
Maximum cutting capacity
12mm
33
Paris 700
10kg
365x160x380
Fan cooled
Inverter power source
EN 60974-1 / IEC 60974-1
3 x 400 Volt ±15%
50/60Hz
20-70A
13.8 A
10A
15KVA
70A@ 60%108V
54A@ 100%101.7V
311V DC
IP23
H
15mm
20mm
PLASMA CUTTING SERIES EQUIPMENT
Description
Weight
Power source dimensions
Cooling
Welder type
European standards
Mains voltage
Grid frequency
Cutting rurrent range
Effective input current
Maximum input current
Generator requirement
Duty cycle, 40°C, 10 min
Open circuit voltage
Schutzgrad
Protection class
Quality cutting thickness (500mm/min)
Maximum cutting capacity
NOTE
Note 1: The Effective Input Current should be used for the determination of cable size & supply
requirements.
Note 2: Generator Requirements at the Maximum Output Duty Cycle.
Note 3: Motor start fuses or thermal circuit breakers are recommended for this application. Check local
requirements for your situation in this regard.
Due to variations that can occur in manufactured products, claimed performance, voltages, ratings, all
capacities, measurements, dimensions and weights quoted are approximate only. Achievable capacities
and ratings in use and operation will depend upon correct installation, use, applications, maintenance
and service.
Summary
Paris 1000
19.5kg
615x225x385
Fan cooled
Inverter power source
EN 60974-1 / IEC 60974-1
3 x 400 Volt ±15%
50/60Hz
20-100A
17 A
21.9A
15KVA
100A@ 60%120V
77.5A@ 100%111V
320V DC
IP23
H
30mm
50mm
34
loading

Este manual también es adecuado para:

Paris 700Paris 500