Truper LIRO-5N Manual página 3

Ocultar thumbs Ver también para LIRO-5N:
Technical data
Code
Description
Base
Voltage
Frequency
Current
Power
Speed
Dust collection
Duty cycle
Conductors
Insulating
Orbit Diameter
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
WARNING
Power requirements
WARNING
Tools with double insulation and reinforced insulation are equipped
with a polarized plug (one prong is wider than the other). This plug will only fit in the
right way into a polarized outlet. If the plug cannot be introduced into the outlet,
reverse the plug. If it still doesn't fit, call a qualified electrician to install for you a
polarized outlet. Do not alter the plug in any way. Both types of insulation eliminates
the need of both a grounded third power cord with three prongs or a grounded
power connection.
WARNING
When using an extension cable, verify the gauge is enough for the power that your product needs. A lower
gauge cable will cause voltage drop in the line, resulting in power loss and overheating. The following table shows the right
size to use depending on cable's length and the ampere capability shown in the tool's nameplate. When in doubt use the
next higher gauge.
Ampere
Capacity
from 0 A and up to 10 A
from 10 A and up to 13 A
from 13 A and up to 15 A
from 15 A and up to 20 A
WARNING
When operating power tools outdoors, use a
extension cable labeled "For Outdoors Use". These extensions are specially designed for
operating outdoors and reduce the risk of electric shock.
50 minutes work per 20 minutes rest. Daily maximum, 6 hours.
18 AWG x 2C with insulating temperature of 221 °F
Class II
0.1"
Number of
Conductors
3 (one grounded)
* It is safe to use only if the extensions have a built-in artifact for over current protection.
AWG = American Wire Gauge. Reference: NMX-J-195-ANCE
LIRO-5N
15399
Variable speed random orbit sander
5"
127 V~
60 Hz
2 A
0.34 Hp
7 000 OPM - 13 000 OPM
Yes
IP Grade
Eccentricity
Power cord grips used in this product: Type "Y".
Build quality: Reinforced insulation.
Thermal insulation on motor winding: Class H.
Extension gauge
from 6 ft to 49 ft
18 AWG( * )
16 AWG
14 AWG
8 AWG
grounded
IP20
0.05"
Authorized Service Center.
|
higher than 49 ft
16 AWG
14 AWG
12 AWG
6 AWG
ENGLISH
3
loading

Este manual también es adecuado para: