VI. STORAGE AND TRANSPORTATION
Storage
The generating set should be started at least once
every two weeks and allowed to run for at least 20
minutes. Follow the instructions below for longer term
storage if the generating set will be out of service for 2
months or more.
DANGER
Fire or explosion
Gasoline is highly flammable and extremely explosive.
Empty the fuel tank and shut off fuel valve before
storing or transporting this generating set.
1. Allow the generating set to cool completely before
storage.
2. Clean the generating set according to the
instructions in the Maintenance section.
3. Drain all fuel completely from the fuel hose and
carburetor to prevent gum from forming.
4. Turn off the fuel supply at the fuel valve.
5. Change the oil.
6. Remove the spark plug and pour about 15 ml of oil
into the cylinder. Crank the engine slowly to distribute
the oil and lubricate the cylinder.
7. Store the unit in a clean, dry area out of direct
sunlight.
Transportation
To prevent fuel spillage when transporting or during
temporary storage, the generating set should be
secured upright in its normal operating position, with
the engine switch OFF.
The fuel valve lever should be turned OFF.
www.ducsonpower.com
WARNING
When transporting:
Do not overfill the tank.
Do not operate the generating set while it is on vehicle.
Take the generating set off the vehicle and use it in a
well-ventilated place. Avoid a place exposed ta direct
sunlight when putting the generating set on a vehicle.
If the generating set is left in an enclosed vehicle for
many hours, high temperature inside the vehicle could
cause fuel to vaporize resulting in a possible explosion.
Do not drive on a rough road for an extended period
with the generating set on board. If you must transport
the generating set on a rough road, drain the fuel from
the generating set beforehand
17