Maintenance of peristaltic pumps
- The pump hose has reached the end of its service life after 500/600 operating hours
(chemical compatibility) and must be replaced annually
- The hoses of the drain and supply pipe must be replaced every two years.
- The nozzles must be descaled and rinsed every two years. The limescale can block the
supply or return. We recommend the use of chlorine with anti-limescale agent
(ZWCX1232).
- The drain and supply pipes must be replaced 2 times a year. .
- A maintenance kit is available: ZWMX2201-Z
- The pumps must always be higher than the supplied liquids.
- Use the correct, prescribed products for the peristaltic pumps and the Santoprene
hose (to be replaced annually as indicated).
Warnings
○
Improper installation may cause an electrical or chemical hazard that could result in
serious injury
○ Never mix acid and liquid chlorine. These react to form dangerous chlorine gas
○ Keep the installation and chemicals out of the reach of children. Always wear protective
gloves and goggles when working on the installation.
○
NEVER make internal adjustments to the dosing unit.
○
If you are not familiar with the pool filter system and the dosing unit:
-
Try not to rent anything without consulting your supplier, a professional pool
contractor.
-
Read the entire installation and operating manual before using the dosing unit.
19