  • Página 1 Nuvia_SelfCleaning-instructions.qxp_Layout 1 10/11/21 09:23 Pagina 1...
  • Página 2 Nuvia_SelfCleaning-instructions.qxp_Layout 1 10/11/21 09:23 Pagina 2 INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE OF SELF-CLEANING FILTERS General Information PLEASE READ THIS INSTRUCTIONS MANUAL THOROUGHLY AND CAREFULLY AND UNDERSTAND ITS CONTENTS BEFORE INSTALLING THE SELF-CLEANING FILTER. - The information in this instruction manual is subject to modifications without prior notice.
  • Página 3 Nuvia_SelfCleaning-instructions.qxp_Layout 1 10/11/21 09:23 Pagina 3 Installation Refer to Fig. A, B and C for installation directions. - Before installation, check if the plumbing system has been set-up according to the applicable plumbing code. - Avoid all kinds of tensions by using a wall bracket. Should the use of the wall bracket be impossible, the installer (qualified and licensed personnel) shall be responsible for the most appropriate installation avoiding tensions which may affect the filter’s integrity.
  • Página 4 Nuvia_SelfCleaning-instructions.qxp_Layout 1 10/11/21 09:23 Pagina 4 - for self-cleaning filter with manometers: unscrew one of the manometers just for a few turns and let all the air being released out the filter until it comes completely filled with water, then tighten the manometer. - After the installation, run the tap and let the water flow for at least 5 minutes before use.
  • Página 5 Nuvia_SelfCleaning-instructions.qxp_Layout 1 10/11/21 09:23 Pagina 5 - Turning-off the valve after a couple of seconds returns pressure distribution to its initial conditions and the internal spring returns the cartridge to its service position (Fig. E2). The filter features a drain funnel, which is a device designed to protect potable water from pollution by backflow.
  • Página 6 Nuvia_SelfCleaning-instructions.qxp_Layout 1 10/11/21 09:23 Pagina 6 MALFUNCTION CAUSE REMEDY Water leaks - Bowl o-ring damaged. - Replace the o-ring. between the filter head and bowl. Water leaks from - Sealant insufficient. - Add a few turns of connections sealing tape. between pipes and from the sides of the filter.
  • Página 7 145 psi (10 bar). ADVERTENCIA: los valores de temperatura máxima de trabajo y de presión máxima de trabajo que se indican en la etiqueta fijada al filtro están entendidos como parámetros máximos de trabajo y no se deben sobrepasar en ningún caso.
  • Página 8 - Se recomienda la instalación de un desvío (By-pass) (consulte la Figura C). - Conectar al embudo de descarga o al acople de goma, ubicado en la base del filtro, un tubo de goma entelada debidamente fijado con una abrazadera y enviado a la descarga (véase figura D1 y D2).
  • Página 9 - Proteja del golpeteo con un dispositivo anti golpeteo. - Si se deja el filtro no en empleo durante más de 1 semana quite el cartucho, limpielo y lo tenga en lugar limpio y seco. Inserte el cartucho atrás en el filtro sólo antes del empleo.
  • Página 10 24 meses y el cartucho de malla de acero al menos cada 48 meses. El vaso del filtro debe ser sustituido con uno nuevo al menos cada 5 años.
  • Página 11 Pérdida de agua - Junta tórica de - Sustituir la junta tórica. entre la cabeza y el estanqueidad del vaso vaso del filtro. estropeada. Pérdida de agua por - Sellador insuficiente. - Agregar algunas vueltas de las conexiones entre cinta de sellado.