8.
Maintenance and Cleaning
8.2.
PLURIS - Decalcifying the evaporator
Hot surfaces - Danger of burns!
Directly after the bath, the heater and/or cover (4) are still hot.
Protect hands and fingers from burns.
Evaporator - draining
1.
Place the filler can (1) under the discharge
opening (2). Open the drain valve (3).
2.
As soon as the evaporator is empty, close the
drain valve (3).
3.
Empty the filler can (1).
Evaporator - decalcifying
4.
Remove cover (4) of evaporator.
5.
Fill the evaporator unit (5) with water.
6.
Add approx. two tablespoons of normal
household decalcifier (chlorine-free!) to the
evaporator unit (5).
7.
Allow the decalcifying mixture to work overnight
(at least 12 hours) on the calcified deposits. The
decalcifying process can be easily repeated
2 - 3 times for the same length of time to ensure
that the entire calcium deposit is dissolved.
8.
Place cover back on (4) evaporator.
9.
Place the filler can (1) under the discharge
opening (2). Open the drain valve (3). Drain
water into the filler can (1).
Evaporator - rinsing
10. Close the drain valve (3).
11. Remove cover (4) of evaporator.
12. Fill the evaporator unit (5) with water.
13. Place the filler can (1) under the discharge
opening (2). Open the drain valve (3).
14. After draining the evaporator, close the drain
valve (3).
15. Repeat the rinsing procedure two or three times.
16. Place cover back on (4) evaporator.
Reset the 92 error on the control panel
17. In standby operation delete the error message
with the OK button.
PAGE 22
Sauna/Infrarot/Softclima/Infraclima
3
4
1
2
1
5
50701103/02.13