Kichler 38260 Manual De Instrucciones página 8

Idiomas disponibles

Idiomas disponibles

ASSEMBLY INSTRUCTIONS (SEMI-FLUSH MOUNT)
B3. Orient the mounting bracket (A) so that the raised
center portion is facing up. Thread extra long
machine screws (FF) through mounting bracket
(A) starting from the outlet box side, so that extra
long machine screws (FF) protrude downward.
Connect mounting bracket (A) to outlet box (not
included) with short machine screws (BB).
Hardware Used
Short Machine
BB
Screw
Extra Long
FF
Machine Screw
B4.
Wire connection guide:
Ground wire:
• For installation in the United States: Wrap ground
wire from outlet box around ground screw on
mounting bracket (A) no less than 2 in. from wire
end. Tighten ground screw. If fixture is supplied with
a ground wire, connect to outlet ground wire with a
wire connector (AA).
• For installation in Canada: If fixture is supplied with
ground wire, wrap ground wire around ground
screw on mounting bracket (A). Tighten ground
screw. Connect fixture ground wire to outlet
ground wire with a wire connector (AA).
Supply wires:
• Connect the Neutral (White) supply wire from the
outlet box to the Neutral fixture wire (White or
Parallel Cord "D" shaped and ribbed).
• Connect the Hot (Black) supply wire from the outlet
box to the Hot fixture wire (Black or Parallel Cord
round and smooth).
Hardware Used
Wire Connector
AA
B3
x 2
x 2
B4
BARE COPPER,
OR GREEN
GROUND
SUPPLY WIRE
BLACK SUPPLY
WIRE
WHITE SUPPLY
WIRE
BLACK SUPPLY
WIRE
WHITE SUPPLY
WIRE
NOTE:
Fixture wires will either be:
x 3
• Black and White.
• Parallel Cord SPT-1 lamp wire with one
round smooth wire and one "D" shaped
ribbed wire.
8
Outlet Box
FF
BB
BARE COPPER,
AA
BLACK FIXTURE
WHITE FIXTURE
OR
PARALLEL
FIXTURE CORD
(ROUND AND
SMOOTH)
PARALLEL FIXTURE
CORD ("D" SHAPED
AND RIDGED)
A
OR GREEN
GROUND
FIXTURE
WIRE
WIRE
WIRE