Installation instruction
AtA Signal
Converter 2 *7252*
Read and follow all instructions. Always follow local
and/or national regulation for installation. AtA Signal
converter 2 should be installed by a qualified
electrician.
The AtA Signal Converter 2 converts a 0-10V dim-
signal to a 1-10V signal. An offset can be set to
ensure that 10% (1V input) will turn the lights on.
The input signal is galvanically isolated to protect the
control unit/climate computer that generates the dim
signal.
The relay output can be used to switch off the HATO
POWER PACK in combination with a bigger relay. This
is a handy future that will save energy by turning off
the power supplies.
The AtA Signal Converter has 3 control modes:
1. Auto mode: output follows 0-10V input.
2. Local manual mode: a push button is used to
control output.
3. External manual control: with external manual
control activated, an external potentiometer controls
output
For external manual control a separate potentiometer
(1KΩ-100kΩ) and switch (SPST) are needed.
Offset is applied in all control modes.
HATO BV
Handelsstraat 31, NL - 6135KK Sittard
www.hato.lighting