MANUAL DE INSTALACIÓN UNIDAD 4GB
INSTALLATION MANUAL OPERATOR 4GB
MANUEL D'INSTALATION OPERATEUR 4GB
R03
loading

Resumen de contenidos para HYDOM 4GB3S33L Serie

  • Página 1 MANUAL DE INSTALACIÓN UNIDAD 4GB INSTALLATION MANUAL OPERATOR 4GB MANUEL D’INSTALATION OPERATEUR 4GB...
  • Página 2 ÍNDICE / INDEX ESPAÑOL ADVERTENCIAS GENERALES PARA LA SEGUIRDAD ........................3 DIRECTIVA DE MÁQUINAS ................................3 DECLARACIÓN DEL FABRICANTE ..............................3 DATOS TÉCNICOS .................................... 4 TIPOS DE MONTAJE ..................................5 INSTALACIÓN ....................................7 REGULACIÓN DE BLOQUEO ................................7 REGULACIÓN DE VELOCIDAD ................................. 8 ENGLISH TECHNICAL DATA .....................................
  • Página 3 ADVERTENCIAS GENERALES PARA LA SEGURIDAD Este manual de instrucciones de montaje está destinado exclusivamente a profesionales cualificados. La instalación, las conexiones eléctricas y los ajustes de regulación deben estar hechos de acuerdo con las normativas vigentes en cada país. Leer atentamente las instrucciones de montaje antes de empezar la instalación del equipo. Una instalación incorrecta puede ser causa de peligro.
  • Página 4 DATOS TÉCNICOS / TECHNICAL DATA / DONNÉES TÉCHNIQUES ATENCIÓN: Para poder acceder a los reguladores, quitar la tapa frontal. CAUTION: To gain access to the pressure regulators, remove the frontal cover. ATTENTION: Pour accéder aux régulateurs, retirez le couvercle avant. FIG.1 FIG.2 ESPAÑOL...
  • Página 5 Datos técnicos / Technical Data / Donnés Téchniques 4GB3S33L* 4GB3S66L* 4GB3S133L* Caudal/Flow/Débit 0.5 L/min 1 L/min 2 L/min Presión máxima/Maximum pressure/Pression maximale 120 bar. 80 bar. 40 bar HYDOIL Tipo de aceite/Fluid to be used/Type d’hulie Rango temp./Temp. range/Plage de temperature C - +80 Capacidad aeite/Fluid capacity/Capacitate d’hulie *L2 = 2L...
  • Página 6 TIPOS DE MONTAJE / TYPES OF ASSEMBLY / TYPES DE MONTAGE Montaje con UP2RU / UP2RU Assembly / Montage en UP2RU FIG.4 Montaje con LIDER / LIDER Assembly / Montage en LIDER FIG.5...
  • Página 7 Conectar las tomas A,B de la 4GB con las tomas A,B de la LIDER. Las tomas C,D sirven para conectar un pestillo hidráulico opcional(Figura 5). REGULACIÓN DE BLOQUEO El grupo hidráulico 4GB de Hydom se entrega configurado de fábrica sin bloqueo. Para configurar otras opciones, deberemos abrir o cerrar el grifo A y/o grifo B con una llave allen de 4mm.
  • Página 8 REGULACIÓN DE VELOCIDAD Para regular la velocidad del grupo hidráulico, se deberá atornillar con una llave allen de 2.5mm el estrangulador que encontraremos en cada uno de los lados de la misma. • Estrangulador del lado del tapón rojo → Regula la velocidad de la toma A.
  • Página 9 GENERAL SAFETY REQUIREMENTS This instruction manual is intended solely for use by qualified professionals. The installation, electrical connections and adjustments must be made in accordance with the current legislation in each country. Carefully read the instructions before starting to install the equipment. Incorrect installation can be dangerous. Packing material (Plastic, expanded polystyrene, etc.) should be disposed of without causing environmental damage and should be kept out of the reach of children, as it is potentially dangerous.
  • Página 10 Connect sockets A,B of the 4GB to sockets A,B of the LIDER. Sockets C,D are used to connect an optional hydraulic latch (Figure BLOCKING SETTING The Hydom 4GB hydraulic power pack is delivered from the factory configured without locking. To configure other options, you will need to open or close tap A and/or tap B with a 4mm Allen wrench.
  • Página 11 SPEED REGULATION To regulate the speed of the hydraulic power pack, the adjustable restrictor on each side of the pump must be screwed in with a 2.5 mm Allen key. • Red plug side throttle → Regulates the speed of socket A. •...
  • Página 12 AVERTISSEMENT GÉNÉRAL DE SÉCURITÉ Ce manuel d’instructions est uniquement destiné à l’usage des professionnels qualifiés. L’installation, les connexions électriques et la mise en service doivent être réalisés en accord avec la législation en vigueur dans chaque pays. Lisez attentivement les instructions avant de commencer l’installation du matériel. Une mauvaise installation pourrait être dangereuse.
  • Página 13 Connectez les prises A et B de la 4GB aux prises A et B du LIDER. Les prises C, D sont utilisées pour connecter un verrou hydraulique optionnel (Figure 5). RÉGULATION DE BLOCAGE Le groupe hydraulique Hydom 4GB est livrée d'usine configurée sans verrouillage. Pour régler les autres options, vous devrez ouvrir ou fermer le robinet A et/ou le robinet B à...
  • Página 14 RÉGULATION DE LA VITESSE Pour réguler la vitesse de le groupe hydraulique, l'étrangleur situé de chaque côté de la pompe doit être vissé avec une clé Allen de 2,5 mm. • Etrangleur côté prise rouge → Régule la vitesse du circuit A. •...
  • Página 16 Manual de instalación 4GB Installation manual operator 4GB Manuel d’instalation operateur 4GB Hidro-Domestics, S.L. Pol. Ind. Les Goules – C/Fusteria 26-30 08551 Tona – Barcelona (Spain) Telf. +34 933 225 661 [email protected] www.hydom.com...

Este manual también es adecuado para:

4gb3s66l serie4gb3s133l serie