Daewoo DAMAX 15 Manual De Uso página 9

Idiomas disponibles

Idiomas disponibles

7. INSTALLATION
The installation space for the charger must be prepared to ensure safety, meet operating requirements.
The user is responsible for the installation and use of the device according to the manufacturer's require-
ments in this manual. The manufacturer is not liable for damages caused by the use and inadequate main-
tenance. The starter and charger must be protected from moisture and rain, mechanical damage, through
wind and possible ventilation of neighboring devices, overload and handling.
After storage in a cold or wet room and after transportation, before going on the device must be left in
normal conditions for at least 2 hours.
1) Avoid installing the unit in open, sunny, with a strong influence of the sun field.
2) Install the unit in a clean, dry, flat surface. One must avoid vibration, dust ingestion of iron, dust and dirt.
3) Install the unit in a dry place without water, to avoid the risk of electric shock.
4) Before starting to clean the contacts and terminals of the charger.
Connect the cable clamps according to the polarity and connect the unit to the network 220V - 50Hz. With
proper installation of the cables to the battery, the unit displays the current value on the ammeter.
5) User actions in the absence of the output voltage / current:
a. Check if the switch is properly set 12V / 24V.
b. Check the settings have not changed from overheating or overloading.
c. Corroborate the fuse.
d. If after these actions the problem persists, contact the service shop.
Attention! Do not reverse the polarity to prevent a short circuit! The ventilation holes of the battery must be
open!
8. CONNECTION TO THE GRID
CAUTION! Connecting the charger to the mains must be performed by a qualified electrician.
Before connecting the charger to the mains, ensure that the size and frequency of the voltage corresponds
to the voltage on the nameplate.
9. MAINTENANCE
ATTENTION!
After work or to find the loader at low temperatures below (+5), do not turn on the unit for 2 hours after
moving it to a warm place, to avoid condensation. Warning: Disconnect power before servicing.
Clean dirt and accumulated inside with compressed air dust regularly. Not directly use the airflow to the
electrical components to avoid damage.
Carry out regular inspections to detect loose connections or frayed wiring, causing overheating and possi-
ble damage.
It is necessary to conduct a thorough inspection at least once a year.
Any changes in the electronic circuit device, the use of non-original parts or in case of a malfunction or
damage, we recommend that you contact our technical service.