Operating
Start (START): Contact normally open to open and close. First time the button is pressed, it opens (until it has reached the
end of run) and the second time it closes. If it is pressed while the door is closing, it will stop and invert the operation (until it
has reached the end of run). If option switch 3 is ON, this button follows the open-stop-close-stop operation.
Stop (STOP): Contact normally closed. This detains the operation on standby for a new order. Where not used, turn option 7
on the input switch to ON.
Pedestrian (PED.): Contact normally open for partial opening. Fixed timer for 10 second opening and 10 second standby for
automatic close.
Ends of run (FC.CL/FC.OP): contacts normally closed to mechanically indicate the open and closed end of run. Where
not used, turn option 5 or 6 on the input switch to ON.
Security edges (S.EDGE): Resistive contact for two parallel resistive security edges. This acts on opening, causing stop-
page and inversion of 1s. This acts on closing, causing stoppage and inversion. Where not used, turn option 3 or 4 on the
input switch to ON.
Security contact (SEC.CL/SEC.OP): Contact normally closed, photocell or magnetic detector type. This acts on opening
and closing, causing stoppage and inversion. Where not used, turn option 1 or 2 on the input switch to ON.
Auto-test outlet (TEST SEC.): 24 Vac outlet for auto-test of security parts.
24 Vac outlet: To power any equipment at a voltage of 24 Vac with a maximum consumption of 300mA.
Garage light contact (COURTESY LIGHT): Timed 230V ac contact for garage light (max. 100W).
Option switch
Option No.
1 (AUTOCLOSING)
2 (NON STOP OP.)
3 (STEP BY STEP)
4 (CLOSE BY SECURITY
CONTACT)
5 (COURTESY LIGHT)
6 (TEST SEC.CL.)
7 (TEST SEC.OP.)
Lower position – OFF
(default option)
Does not close automatically Automatic closure
Allows for reverse on open-
ing
Start button/transmitter with
open-close-open function
The security edge close car-
ries out its normal function
Garage light contact time = 1
seconds
No autotest carried out
No autotest carried out
jcmtechnologies
Upper position – ON
Does not allow for reverse on opening
Start button/transmitter with open-stop-close-
stop-open function
The security contact close also activates the
closing button after the vehicle has passed
Garage light contact time = operation time + 30
seconds
This carries out the autotest for the security
close contact
This carries out the autotest for the security
open contact