LCD Electronic Thermostat
Code: 0769004,
Reference: KT4-LCD-NP
Before Installation
Turn off 0769004, all electronic source and electrical devices
which will be connected before installation and maintenance.
The installer must be a trained service personnel.
Installation Location
The thermostat should be mounted on an inner wall ~1.5m above the floor in a position
where it is readily affected by changes of the general room temperature with freely
circulating air.
Prevent direct exposure to sunlight, drip or splash.
Do not place the unit at a location where air circulation is low, or where there are great
temperature changes (e.g. near door). Do not place the thermostat near heat generating
sources (e.g. radiators, hot air vents, TV or lights).
Wiring the Terminal
For 0769004, there are 3 wiring terminals at the back of the thermostat which are labeled
as "NC", "NO" and "L". Connect L to Live and NO to Heater or Cooler. Where NC is a
Normally Close Valve.
Mounting
1. Ensure that the surface is level.
2. Place the cables at the hole near the terminal block.
3. Insert 2 pcs of wall anchors into the holes of the wall.
4. Fasten the thermostat with 2 pcs of long screws through the 2 mounting holes as
shown in the below figures.
Opening
Pull out the battery drawer and then lightly press on the spots shown below in order to detach
the front shell from its base.
Start / Reset
When the system is reset, all the LCD segments are ON and the measured temperature will be
displayed after a while. Low Battery Check will be done at startup. when battery is low,
will be displayed and please replace the battery.
*If there are any display or functional errors, please remove the batteries for about 30
sec to reset the thermostat.
Normal Display Mode
1. Temperature detection starts and LCD displays the room temperature.
2.
Below 0°C / 32°F, 0769004 will display LO.
3.
Above 40°C / 99°F, 0769004 will display HI.
4.
Press <Up> / <Down> to adjust Heat / Cool setting temperature.
5.
Press <Mode> to select Heat / Cool / Off Mode
- By default, press <Mode> to switch from Off to Heat or vice versa
- To switch to Cool Mode, press & hold <Mode> for 2 seconds in Off Mode.
- Cool Mode will then be activated.
- Use the same method to change back to Heat Mode.
6.
Defrost function will be activated with
displayed when temperature is below
5°C / 40F in either Heat or Off Mode in Heat / Off pair. Heater is on regardless of the
setting temperature.
Temperature Setting
To adjust heat/ cool setting:
1.
Press <Up> or <Down> keys to adjust Heat / Cool setting temperature in normal display
mode.
2.
Heat/ Cool setting temperature flashes.
3.
In Heat Mode, only heat setting temperature can be adjusted.
4.
In Cool Mode, only cool setting temperature can be adjusted.
5.
In Off Mode, no setting temperature can be adjusted.
6.
The operation will resume to normal display mode after no key is pressed for 10 sec.
Function Setting
1.
Press and hold <Backlight> and <Down> keys for 2 seconds.
2. LCD changes to the display of Function Setting selection.
3. Press <Up> / <Down> to adjust Function Type/ Setting.
4. Press < NEXT > to select Function Type/ Setting.
5. Press <ENT> to return to the normal display mode.
Function
Type
<ENT> key
Table of the Internal Setting:
Function Type
HS Span of Heater
dU Temperature Display Unit
CS Span of Cool
Compressor/ Heater
Cd
Minimum-Off Delay
* When function type is being selected, output "NO" will be turned off
automatically and 0769004 will enter Off Mode.
Replace Batteries
.
1.
Choose the right type of batteries and install them with proper polarity.
2.
Do not mix old and new batteries.
3.
Remove batteries if they are used up or the thermostat will not be in used for a
period of time.
4.
Use 1.5V/cell alkaline batteries 2 pieces.
Maintenance
Caution: Switch off all electric sources before maintenance. We recommend
that the maintenance should be performed by a
trained personnel.
No heating / cooling control:
Check the thermistor sensor performance by measuring the corresponding
variable resistance under different temperatures, if it is in good condition, the
LCD value will change accordingly, if not, trace the control circuit or the
LCD connection, replace the thermistor sensor if necessary. If there is a
problem with the control circuit, replace the PCB if necessary.
Specification
1.
Temperature Measurement:
2.
Accuracy:
3.
Temperature Controllable Range:
Heat/Cool Setting:
4.
Resolution:
5.
Power Supply:
6.
Rating:
7.
Terminals:
8.
Operating Temperature:
9.
Storage Temperature:
10. Sensing Element:
Degree of Protection:
11.
TEMPER ENERGY INTERNATIONAL S.L.
Polígono industrial de Granda, nave 18
33199 • Granda - Siero • Asturias
Teléfono: (+34) 902 201 292
Fax: (+34) 902 201 303
www.grupotemper.com
Setting Value
<Up> key
<Down> key
<NEXT> key
Setting
+/- 0.3C / 0.5F (by default)
+/- 0.5C / 1F
C (by default)
F
+/- 0.3C / 0.5F (by default)
+/- 0.5C / 1F
1
1 minute compressor off delay (by default)
2
2 minutes compressor off delay
3
3 minutes compressor off delay
4
4 minutes compressor off delay
5
5 minutes compressor off delay
0 ~ 40C / 32 ~ 99F
±0.5C/ 1°F
5 ~ 35C / 40 ~ 95F
0.1C /0.5°F
2 x AAA alkaline batteries
230Vac ~ 50/ 60Hz, 5(1)A.
2
2mm
cable
0 ~ 50°C / 32 ~ 122°F
-5 ~ 50°C/ 23 ~ 122°F
NTC thermistor
IP-20
140826