Pahlen WaterVISE Manual De Usuario página 10

Ocultar thumbs Ver también para WaterVISE:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
Pump WaterVISE, FloVISE
General information
Pahlen pumps are manufactured in accordance with the applicable standard and certified by the third party.
Modification or change of the product must only be made after receiving the manufacturer's approval. Only use spare parts and
fittings approved by the manufacturer.
For Pahlen's standard pools, the pool water must not be aggressive, see the record water values below.
Transport and season storage:
Store the pump in a dry environment in a temperature as stable as possible (Great temperature changes and moist environment
can lead to corrosion damages on motor coils or metal parts).
Safety
• The pump must only be used within the limit values given on the pump type plate and motor rating plate.
• Make sure that the pump type plate and the motor rating plate are readable even after the installation.
• Do not use the pump without its protective housing. Touching live or moving parts can cause serious damage.
• Always check that the current to the pump is disconnected before commencing any work, service or maintenance of the pump.
• Make sure that the right dimension of pipe to and from the pump is used, see the table on the next page. This reduces the risk
of pressure drop, which can lead to cavitation damages on the pump's mechanical parts.
• If there is a freezing hazard, the pump must be disconnected and drained out to avoid frost damages.
Product description
The pump is intended for circulation of filtered water in pools with chlorine disinfection (organic, inorganic chlorine).
Pahlén can not guarantee the pump's lifespan and operational performance with other types of disinfection agents.
The pre-filter enclosure can be dismantled, which allows the inlet direction to be turned without affecting the pump's
performance This is provided to facilitate placing the pump in an area where the installation space is limited.
Function
Suction side (A) - the pump sucks water.
The water passes through the pre-filter (B), which has an inner strainer bucket, and further into the pump housing.
The water is pumped/pressed further out of the pump housing on the pressure side (D).
Discharge valves (E) are opened during the draining of the pre-filter and pump housing.
F
The product is intended for the following water values:
Total chlorine:
max 3.5 mg/l *
Chloride (salt) content: max 250 mg/l
PH-value:
7.2 - 7.6
Alkalinity:
60-120 mg/l (ppm)
Calcium hardness:
100-300 mg/l (ppm)
Iron:
max 0.1 mg/l*
Copper:
max 0.2 mg/l*
Manganese:
max 0.05 mg/l*
Phosphorous:
max 0.01 mg/l*
Nitrate:
max 50 mg/l*
The product guarantee does not apply outside these values.
Pump type plate
Motor rating
plate
* According to SS-EN 16713-3 2016
10
ENGLISH
E
C
D
Picture 1
A
Suction side
B
Prefilter housing
C
Pump housing
D
Pressure side
E
Lock handle
F
Drain plug
A
B
loading

Este manual también es adecuado para:

Flovise