Novoferm tormatic T100 DES Manual De Instrucciones Y De Montaje página 25

Control de portón
Ocultar thumbs Ver también para T100 DES:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 54
Representation of the menu structure
Menu
Menu item
1.
Activation of programming
2.
Menu selection
3.
4.
5. Confirmation of the
menu item selection
6. Setting of the desired value
7. Confirmation of the
setting
8. Navigation to the next
menu item or to exit
the programming
menu
9. Exit programming
Selection
Confirmation of the
main menu selection
Selection of the menu
item
Exit
Menu 3 basic settings and initial operation
Setting the door end positions (menu items 30 and 31)
The upper and lower limit switch must be set directly in succes-
sion.
1.
Select menu  3 "Basic settings" in the control and go to
menu item 30 "Door setting of upper end position", so that
the number 30 blinks on the display.
2.
In order to define the upper end position, keep the but-
ton 
pressed until the door is completely open.
ð
If the door moves in the wrong direction, a reversal of
the direction must be implemented. Keep the button 
pressed for 5 seconds and then repeat step 2.
3.
When the upper end position has been set, the lower end
position must be adjusted. Exit menu item  30 by pressing
the button 
once. The numeric point on the LED display
blinks 5 times and in this way confirms the entry.
4.
Switch to menu item  31 "Door setting of lower end posi-
tion".
5.
In order to define the lower end position, keep the button 
pressed until the door is completely closed.
6.
Confirm the entry to complete the setting process.
The door must be spring balanced.
NOTICE
Depending on the driven the door must be spring
balanced.
Crush hazard and risk of being struck by the
WARNING
closing door
Ensure that no closing edge or photoelectric
sensor monitoring is active whilst the end posi-
tions are set.
Setting the 1/2 door opening (menu item 32)
To set the position for a 1/2 door opening, proceed as follows:
1.
Select menu  3 "Basic settings" in the control and go to
menu item 32 "Door setting 1/2 opening".
2.
Press the 
 button and keep it pressed until the door has
reached the desired position.
3.
Confirm the entry to complete the setting process.
Fine adjustment of the door end position at the top (menu
item 33) and at the bottom (menu item 34)
1.
Select menu  3 "Basic settings" in the control and go to
menu item 33 "Fine correction upper end position".
ð
The preset value 50 blinks on the LED display.
2.
Values 0 to 99 are provided to you for carrying out a fine
correction. Values of 50 (default setting) to 0 correspond to
0 mm to approx. -80 mm. Values from 50 to 99 correspond
to 0 mm to approx. +80 mm.
3.
Confirm the entry and switch to menu item 34 "Fine correc-
tion lower end position".
4.
Values 0 to 99 are provided to you for carrying out a fine
correction. Values of 50 (default setting) to 0 correspond to
0 mm to approx. -80 mm. Values from 50 to 99 correspond
to 0 mm to approx. +80 mm.
Selection of closing edge  J3 / selection of photoelectric
sensor J4 (menu items 35 and 36)
1.
Select menu  3 "Basic settings" in the control and go to
menu item 35 "Closing edge selection".
2.
Select a value corresponding to the desired setting.
3.
Confirm the entry and switch to menu item  36 "Photoelec-
tric sensor selection".
4.
Select a value corresponding to the desired setting.
5.
Confirm the entry to complete the setting process.