A: Connector to valve
B: Schedule indicator
C: Automatic / Manual mode indicator, open window in-
dicator and comfortable / energy saving mode indicator.
D: Holiday mode indicator and day of the week
E: Menu key
F: Rotary selector
G: Date / Temperature
H: Battery status
I: Comfort mode / Energy saving mode
S: Confirm
Start up
1. Insert the batteries into the thermostatic valve. 2 x
1.5 AA LR6
2. Adjust the Date and Time, using the rotary selector
and the "confirm" key, until the text "ADA" appears on
the screen.
3. Install the valve on the radiator.
No special tools are required, or turn off the heat. The
union nut attached to the radiator thermostat can be
used universally and without accessories for valves from
most manufacturers with a thread size of M30 x 1.5 mm.
39