Temperature setting: 5 °C to 35 °C in 0.5 °C increments
Temperature differential: 0.2 °C
Operating temperature: 0 °C to 40 °C
Storage temperature: -20 °C to 60 °C
Unit interconnection: via 868 MHz radio signal
Transmitter unit range: up to 100 m in an open area
Power supply:
Control unit (transmitter): 2× 1.5 V AAA batteries
Switching unit (receiver): 230 V AC/50 Hz
Dimensions and weight:
Control unit: 28 × 120 × 77 mm; 117 g
Switching unit: 26 × 86 × 86 mm; 146 g
Display Description (See Fig. 1)
1 – operating mode
2 – cooling mode
3 – low battery indication
Control Button Description
Thermostat (Transmitter Unit) (See Fig. 2)
1 – control/confirmation button
Receiver (Switching Unit) (See Fig. 3)
2 – main switch
position – off
position – on
Rear of the Thermostat (See Fig. 4)
5 – LEARN button for pairing units
Procedure for Removing the Front of the Thermostat (See Fig. 5)
2, 3 – use a screwdriver to press down and hold the inner lock, remove
the front cover.
Procedure for Removing the Front of the Switching Unit (See Fig. 6)
2, 3 – use a screwdriver to press down and hold the inner lock, remove
the front cover.
INSTALLATION
Warning:
Before changing the thermostat, disconnect the heating/air-conditioning
system from the main power in your flat. This will prevent potential injury
by electric current.

Thermostat Installation

The rear of the thermostat carries 4 openings for mounting onto a wall.
Use the enclosed screws and wall plugs to mount the thermostat.
4 – set temperature
5 – room temperature
6 – heating mode
3 – M/A button (red LED)
4 – MANUAL button (green LED)
5