Character
n
0L
in
U
f
M...
Ø
HM
Fe 400
HSS
Fe 400
HSS
Fe 400
T
a
L
pA
L
wA
L
pCpeak
K...
h
For your safety.
Read all safety warnings and all
WARNING
instructions. Failure to follow the
warnings and instructions may result in electric shock,
fire and/or serious injury.
Save all warnings and instructions for future reference.
Do not use this power tool before you have
thoroughly read and completely understood this
Instruction Manual and the enclosed "General
Safety Instructions" (document number
3 41 30 465 06 0). The documents mentioned should
be kept for later use and enclosed with the power tool,
should it be passed on or sold.
Please also observe the relevant national industrial
safety regulations.
Intended use of the power tool:
Magnetic core drill unit for drilling with core drill bits
and solid drill bits, countersinking and tapping on mate-
rials with surfaces suitable for magnets in weather-pro-
tected environments using the application tools and
accessories recommended by FEIN.
The carrying handle is used for transporting the
machine.
Unit of measure-
Unit of measure-
ment, international
ment, national
-1
/min, min
, rpm,
rpm
r/min
inch
inch
V
V
Hz
Hz
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
kg
kg
°C
°C
dB
dB
dB
dB
dB
dB
2
m/s
m/s
2
m/s
m/s
m, s, kg, A, mm,
m, s, kg, A, mm,
V, W, Hz, N, °C,
V, W, Hz, N, °C,
2
dB, min, m/s
dB, min, m/s
Explanation
No-load speed (anticlockwise)
Size
Rated voltage
Frequency
Size of metric thread
Diameter of a round part
Max. capacity in steel with up to 400 N/mm
– TCT (core drill bit)
Max. capacity in steel with up to 400 N/mm
– high speed steel (core drill bit)
Max. capacity in steel with up to 400 N/mm
– high speed steel (twist drill bit)
Max. drill chuck capacity
Counterboring diameter
Weight according to EPTA-Procedure 01
Allowable ambient temperature
Sound pressure level
Sound power level
Peak sound pressure level
Uncertainty
2
Vibrational emission value according to
EN 62841 (vector sum of three directions)
2
Mean vibrational value for core drilling
Basic and derived units of measurement from
the international system of units SI.
2
In environments subject to interference, a reduction of
the operating quality is possible; this can include tem-
porary failure, temporary reduction of the function or
the intended operating behaviour, for the correction of
which intervention by the operator is required.
This power tool is also suitable for use with AC gener-
ators with sufficient power output that correspond to
the Standard ISO 8528, design type G2. This Standard
is particularly not complied with when the so-called dis-
tortion factor exceeds 10 %. When in doubt, please
refer to the generator instruction/specification guide.
Observe the operating instructions and the national
regulations for the installation and operation of the AC
generator.
WARNING
exceeds the voltage value on the type plate of the
power tool is prohibited.
Operating the power tool off power
generators whose no-load speed
en
23
2
2
2