EN
IOT Reset Button and Light
This light is usually off. When the button is pressed once, the light flashes
green, and SHP Bluetooth allows pairing for five minutes. If the user pairs
with the SHP, the light stays green. If nothing pairs with the SHP, Bluetooth
goes into sleep mode, and the light turns off.
Circuit Control
The circuit control consists of three parts, the circuit index number, the
reset button, and the power indicator. The reset button is used to reset
the circuit if there has been a fault in that circuit. If that circuit is white, it is
powered by the grid power and green when powered by the DELTA Pro.
The lightning-shaped power indicator indicates whether that load circuit is
energized or not.
Error Indicator
If there is no fault with the SHP, this light is off. It will flash red if there is
any fault in the product. Check the App for a fault diagnostic report and
reach out to an EcoFlow customer support representative for help.
Note
If there is a relay module fault, only the faulty channel will default back to grid mode. For other
faults, all channels may default to grid mode.
3.4 APP
Control and monitor EcoFlow portable power stations and the SHP remotely with the EcoFlow App.
Download at: https://download.ecoflow.com/app
Privacy Policy
By using EcoFlow Products, Applications, and Services, you consent to the EcoFlow Terms of Use and
Privacy Policy, which you can access via the "About" section of the "User" page on the EcoFlow App
or the official EcoFlow website at https://ecoflow.com/pages/terms-of-use and https://ecoflow.com/
pages/privacy-policy.
6
ERROR