Avoid any type of thermal and mechanical stress on flexible hoses during installation and use (protection
against traction, twisting, crushing, etc.).
CAUTION!
Perform maintenance and periodically replace the flexible hose within the expiration date
written on the sheath. Do not use expired or damaged flexible hoses by any means.
GAS CONNECTION PROCEDURE
The appliance is supplied with a gas train with a
smooth end section and free for at least 30 mm, fit
to house suitable press fittings. Proceed as follows
to set up the gas connection:
step
1
Connect the Ø 8 mm pipe to the compression
fitting prepared by the installer for connection to
the gas supply network.
2
Test the connection with a suitable instrument
for leak testing or use a liquid solution.
CAUTION!
During the installation and connection
operations, the gas supply pipe of the
appliance must not be subject to twisting,
traction or any other mechanical stress
which could jeopardise tightness and
strength.
After connecting the equipment to the gas mains, check the fittings to make sure they are sealed by using
a solution of water and soap or a testing device for pressure leak tests. Gas installation technicians usually
have them.
CAUTION!
During installation, connection and use, the gas supply hose of the appliance must not be
twisted, pulled or subjected to any other mechanical/thermal stress which may jeopardise its
tightness and resistance.
CAUTION!
It is absolutely prohibited to use naked flames to check tightness and to put the device into
service! If the test is satisfactory, light all the burners to make sure that the flame is regular
and stable.
action
Installation, use and maintenance instruction manual
EQUIPMENT REQUIRED
Please note: the fittings* are not supplied with the product.
They are solely supplied and connected by the installer.
Some versions are already provided with a nut and metal ogive
pre-mounted on the gas train.
▪
Ed. 01/2021 Rev. 01
49