4. Select the type of unit the Connect CRP is connected to
The available settings are:
FULL ELECTRIC
Monobloc or split heat pump, with or without stor-
age tank and without the aid of a boiler as sup-
port
HYBRID H
Hybrid system for room heating/cooling and
DHW production, consisting of heat pump and
boiler as support, with or without storage tank
HYBRID C
Hybrid system for room heating/cooling, consist-
ing of heat pump and instantaneous boiler as
support. DHW production is only with boiler.
5. Activate/deactivate the "DIGITAL INPUT" function in
accordance with the system settings.
NOTE For correct configuration, the system config-
uration must be scrupulously followed.
NOTE When this function is active the system will
follow its own setpoint and will not be managed by
the Connect CRP (for a correct set point setting, re-
fer to the system manual).
NOTE With the digital inputs enabled, it will not be
possible to set the climatic curves.
6. Set the number of zones with the
tons and confirm with the
Up to 8 different zones can be set. With the exception of "Zone 1" (default CRP), the other zones, if present, must be
paired to their own thermostat for correct operation (to pair an RF device, see Annex 2).
In any case, an RF device can be paired with zone 1. In this case, the Connect CRP will work only as a remote con-
troller, losing the thermostat function; Zone 1 will be managed on the temperatures detected by the paired RF device.
NOTE
By default each zone has its own name assigned (modifiable at a later time):
Zone 1: CRP
Zone 2: BEDROOM
and
but-
button.
Zone 3: BATHROOM
Zone 4: BEDROOM 2
cod. 3542B390 - Rev 00 - 06/2022
S Y S T E M T Y P E
F U L L E L E C T R I C
H Y B R I D H
H Y B R I D C
I N S T A L L E R
fig. 15 - Type of system
NOTE
For correct system setup, refer to the unit model.
D I G I T A L I N P U T S
F U N C T I O N N O T A C T I V E
F U N C T I O N A C T I V E
fig. 16
I N S T A L L
N U M B E R O F Z O N E S
U S E A R R O W K E Y S T O M O D I F Y
fig. 17
Zone 5: KITCHEN
Zone 6: BATHROOM 2
Zone 7: DINING
Zone 8: HALL