Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

NOTE: Keep your receipt and these instructions for proof of purchase.
NOTE: Dispose used products according to local regulation.
WArNING: Shut off the power at the circuit breaker or fuse panel before removing
the old fixture, ballast, or fluorescent tubes.
If you are unfamiliar with electrical installations, we recommend you contact
a qualified electrician to do the installation.
NOTE: Two people are recommended for installation of this light fixture.
NOTE: MOUNT THIS EQUIPMENT AT LEAST 2.3 M ABOVE THE FLOOR.
It is the Installer's responsibility to verify safe ozone concentrations by taking into
account the number of products in a given volume of space, the characteristics of the
ventilation system, access, and other factors.
HArDWAre AVAILABLe TO PUrcHASe
Hardware kits for surface mounting and suspension mounting are sold as separate accessories. Please contact ETi SSL Customer Service 1-855-384-7754 for additional information.
Part
Description
AA
Aircraft Cable for Suspension Mounting
INSTALLATION
NOTICE: Select a suitable location that can support the weight of the fixture.
Determine the method of mounting before beginning installation.
CAUTION: Installer is responsible to ensure grid location is rated for fixture weight
prior to installation. If uncertain, use cable to support fixture from the retention clips
to a suitable support structure. Failure to do so can cause serious injury.
1
Open the package and remove the EPE foam, then take out the UVC lamps.
2
Slightly press the small cover with the finger, and remove the screw with the
screwdriver, then open the small cover.
3
Keep the small cover at 90 degree to the front panel. Grab the edge of the front panel
with your fingers, and then slightly pull out the front panel.
4
Open the front panel, unplug the ground wire between the front panel and fixure from
the connector terminal, then take down the safety rope.
5
Hold the end of the UVC lamp, press the lamp socket onto the clips of the base. Push in
the direction as shown, make the distance of two clips bigger, and then hold the lamp
socket.
6
Rotate the UVC lamps in the direction as arrow. Slightly push it into the clip.
7
Install the safety rope and the front panel, then connect the ground wire. Open
the small cover and keep it at 90 degree to the fixture surface. Install the front
panel to the fixture and check if tighten, use the screw to lock the small cover
by screwdriver.
8
Shut off power at the electrical panel before beginning the installation.
9
Remove existing fixture and set aside to recycle in accordance with local requirements.
MAkINg eLecTrIcAL cONNecTIONS
10
Remove the driver box cover plate and punch out the knock out hole.
11
Feed the conduit or Romex (based on local electrical code) through the knock out hole.
NOTE: It's recommended to use 16GA pigtails from the terminal block to the respective power supply wires. Must add pigtail or jumper wires into the ACL and ACN terminal
to use a wire larger than 16AWG for both AC and Neutral Line.
Make the electrical connections: Connect black (L) wire with black wire in the driver. Connect white (N) wire with white wire in the driver. Connect ground wire with green
12
wire in the driver. If a 0-10v dimming circuit is available, connect fixture purple wire to driver DIM+ and pink fixture wire to driver DIM-.
13
Tuck wires inside the driver box and reattach the driver cover.
grID ceILINg INSTALLATION
Bend each of the mounting clips on the back of the fixture upward and then twist the top 90°.
14a
Place the fixture into the ceiling grid, hook the mounting clips over the grid ceiling supports and
make sure it is secure.
USE AND CArE GUIDE
2x4 UVC PLASMA FLAT PANEL
Quantity
Part #
4
95457326101
PAckAge cONTeNTS
Part
Description
Quantity
A
Fixture
1
B
UVC lamps
2
C
Wire Connector
5
B
x 2
Step1:
Step3:
UVC lamp
Step5:
Lamp socket
base
Push in the direction
Push in the
Press the lamp
direction as
socket to the base
and then finish
arrow
the installation.
Model # 559041110
Part # SAFP-24-LB4-8-CP4-MV-LVD
C
AA
Step2:
Step4:
ground wire
Step6:
clips
A
front panel
safety rope
Tabla de contenido
loading

Resumen de contenidos para Silentaire 559041110

  • Página 1 Model # 559041110 Part # SAFP-24-LB4-8-CP4-MV-LVD USE AND CArE GUIDE 2x4 UVC PLASMA FLAT PANEL PAckAge cONTeNTS NOTE: Keep your receipt and these instructions for proof of purchase. NOTE: Dispose used products according to local regulation. Part Description Quantity WArNING: Shut off the power at the circuit breaker or fuse panel before removing Fixture the old fixture, ballast, or fluorescent tubes.
  • Página 2: Cleaning The Filter

    SUSPeNSION MOUNTINg Quick Cable Lock Mounting Clips Bend each of the mounting clips on the back of the fixture upward. Depending on mounting location, Connect the mounting clips to the aircraft cables by using S hooks. install 8 toggle bolts into drywall Adjust the aircraft cables to level the fixture.
  • Página 3 rePLAce THe UVc LAMP clips • Slightly pull out the UVC lamps from the clip, rotate the UVC lamps in the direction as • After replacing, install the safety rope and the front panel, then connect the row till it’s vertical to fixture. Hold the end of the UVC lamps and then take it out from ground wire.
  • Página 4: Contenu De L'emballage

    Modèle n° 559041110 N° de pièce SAFP-24-LB4-8-CP4-MV-LVD GUIDE D’UTILISATION ET D’ENTrETIEN PANNEAU PLAT PLASMA UVC 2x4 cONTeNU De L’eMBALLAge rEMArQUE: Gardez votre facture ainsi que ces instructions comme preuves d’achat. Pièce Désignation Quantité rEMArQUE: Éliminer les produits usagés conformément à la Luminaire réglementation locale.
  • Página 5: Montage En Suspension

    MONTAge eN SUSPeNSION Câble antivol rapide Clips de montage Pliez chacun des clips de montage à l’arrière du luminaire vers le Selon l’emplacement de montage, haut. Connectez les clips de montage aux câbles de l’avion à l’aide de installez 8 boulons à ailettes dans la crochets en S.
  • Página 6 reMPLAcer LA LAMPe UVc clips • Retirez légèrement les lampes UVC du clip, faites pivoter les lampes UVC dans le sens • Après le remplacement, installez la corde de sécurité et le panneau avant, puis de la rangée jusqu’à ce qu’elles soient à la verticale du luminaire. Tenez l’extrémité connectez le fil de terre.
  • Página 7: Contenido Del Paquete

    Modelo # 559041110 Parte # SAFP-24-LB4-8-CP4-MV-LVD MANUAL DE USO Y CUIDADO PANEL PLANO PLASMA DE UVC 2x4 cONTeNIDO DeL PAQUeTe NOTA: Guarde su recibo y estas instrucciones como comprobante de compra. NOTA: Deseche los productos usados de acuerdo con la normativa local.
  • Página 8: Montaje De Suspensión

    MONTAJe De SUSPeNSIÓN Bloqueo de cable rápido Clips de montaje Doble cada uno de los clips de montaje en la parte posterior de la Dependiendo de la ubicación de montaje, lámpara hacia arriba. Conecte los clips de montaje a los cables de instale 8 pernos de palanca en paneles de la aeronave usando ganchos en S.
  • Página 9: Mantenimiento

    reeMPLAZO De LA LÁMPArA UVc clips • Saque ligeramente las lámparas UVC del clip, gire las lámparas UVC en la dirección de • Después de reemplazar, instale la cuerda de seguridad y el panel frontal, luego la fila hasta que quede vertical con respecto a la lámpara. Sostenga el extremo de conecte el cable a tierra.

Este manual también es adecuado para:

Safp-24-lb4-8-cp4-mv-lvd

Tabla de contenido