Model:SR3001
Before using or installing this sensor, kindly read the instructions and follow safety rules or let the qualified
company mount it.
Thank you for choosing the item of company PANLUX s.r.o.
Technical datas
Input voltage: 230V~50Hz
Power: 0,9W
Detection angle: 360°/160°
Reach: 1-8m, adjustable
Protection: IP20
Sensor SR3001 is an active motion detector, it emits high-frequency electro-magnetic wave (5,8GHz). When
the sensor detects the slightest movement in the light´s detection zone, it triggers the light on. Detection is
possible through doors, panels of glass or thin walls.
Installation
Before installation make sure that the sensor is disconnected from power supply. Take down the top cover (pic.
1) and then tighten off the two screws fixing middle cover (pic. 2). Hold the base against the wall and mark
drill holes, paying attention to any existing wiring in the ceiling. Drill holes, insert wall plags (6mm dia.). Put
the power wire and load wire through the base holes. Screw the base into chosen place (pic. 3). Connect the
mains power supply and the load wire to the connection terminal according to connction-wire mark. Close the
middle cover and adjust knob to setting.
Fit the top cover and try the sensor..
Conneting illumination
connect N, L with power
connect N, L´with load (lighting fixture)
N L ' L
Reach setting (sensitivity)
Reach is the term used to describe the radii of the circular detection zone produced on the ground
after mounting the sensor light at a height of 2,5m. Turn the reach control to adjust the radii from 1m
to 8m.
Time setting
The light can be set to stay ON for any period of time between approx. 8 sec +/-5sec to max. 12 min.
+/-30sec. Any movement detected before this time elapse will re-start the timer. It is recommended to
select the shortest time for adjusting the detection zone.
8sec~12min
Light-control setting
The chosen light response threshold can be infinitely from approx 2 LUX to 2 000LUX +/- 5%. The
knob must be fully clockwise when adjusting the detection zone.
I
2~2000LUX
If the sensor is mechanically damaged, guarantee cannot be allowed.
RADAR SENSOR - ceiling
Load:
max. 1200W (light bulb)
max. 600W (fluorescent light)
HF system: 5,8GHz CW radar, ISM band
Installation sit: indoors, ceiling