possible, away from draughts (windows, doors) or anything else that could interfere with its
control. This will provide the best thermal comfort. Place any object that could impede air
circulation (furniture, armchairs) 50 cm from the front of the appliance. The product must
not be placed in front of or directly below a fixed socket. The bottom of the control panel
must be at least 15 cm above the floor.
For any prodcut, if the power supply cable is damaged, it must be replaced with a specific
cable. The replacement of the cable must be carried out by ROINTE, our after-sales service
or qualified personnel. The technical characteristics of your product are indicated on the
technical characteristics label.
This product complies with CLASS II safety standards. It can be installed in Zones 2 and 3,
positions A and B provided that the following rules are observed:
In bathrooms, the product must never be installed in such a way that the control panel can be
reached by a person in the bath or shower. The control panel must be located at a minimum
distance of 600 mm from any wet areas. The body of the product can be placed in Zone 2
if the control panel is located within Zone 3.
WARNING: The weight of some of the products may be heavy. The
installation may require two people.
IMPORTANT: Please follow these instructions carefully.
An installation kit is included in the packaging. Follow the instructions below:
1. Select the appropriate place on the wall.
2. Place the mounting template on the wall, making small marks where the holes are to be
located.