Suntec Wellness KLIMATRONIC DryFix 12 EQ Manual Del Usuario página 11

Tabla de contenido
The device does not
dehumidify.
The air does not flow out.
Loud noises during start up.
Error Code
In case of complaint
You can claim the device within 24 months from date of purchase (receipt).
A free replacement or repair will be excluded from prior improper product handling.
Defects in wear parts, consumables, as well as cleaning, maintenance or replacement of said parts
are therefore with costs.
If you want to make a complaint, please bring the entire device in its original packaging and with
proof of purchase to your dealer. For a timely and convenient service register, visit our website
www.suntec-wellness.de
Without a proof of purchase, generally there will be no repair or replacement.
In the event that the complaint case is analogous to our terms of service, all defects of the device or
its accessories due to material or manufacturing defects will be eliminated by repair or, at our
discretion, replacing the unit.
The damage of accessories does not automatically lead to a free exchange of the whole device. In
these cases, please contact your dealer. Glass breakage, or breakage of plastic parts are always to
charge.
The dealer or repair service can perform the repair after the expiration of warranty against charge.
REFRIGERANT
(CE) N 842/2006: This dehumidifier contains the refrigerant R290. The amount of refrigerant is less than
1kg, and is in a closed cooling circuit. The coolant does have zero ozone depletion potential, but is a so-
called greenhouse gases under the Kyoto Protocol and may thus contribute to global warming, if it is
released to the atmosphere. Therefor only trained technicians with refrigerant certificate make a filling or
emptying. Suntec your dehumidifier does not have to use if used properly and undamaged coolant
circuit can be refilled with refrigerant.
R290, GWP: 3, 50g = 0.000150t CO2e
SUNTEC WELLNESS GMBH / HOLZSTRASSE 2 / 40 221 DÜSSELDORF / GERMANY
The unit is in defrost mode.
Is the air inlet or outlet blocked?
Is the ambient temperature or
relative humidity too low?
Is the air filter dirty?
Is the air inlet or outlet blocked?
If the device was placed awry or
unstable?
Is the air filter dirty?
E2
Humidity sensor damaged or
failed.
CL
Room temperature is below 5°
C.
CH
Room temperature is above
35°C.
LO
If the relative humidity in the
room is below 20%.
HI
When the relative humidity in
the room is above 90%.
and learn more.
© 2022 KLIMATRONIC
This is a normal process and
helps to protect internal parts.
Once the process is complete,
the unit returns to normal
operation.
Check the air inlet and outlet
and remove any obstructions.
Please check the settings on
the unit. If the set humidity is
below the ambient humidity and
/ or 20%, the unit stops
dehumidifying.
Clean the air filter as described
in the manual.
Check the air inlet and outlet
and remove any obstructing
objects if necessary.
Place the unit on a stable flat
surface.
Clean the air filter as described
in the manual.
Please contact your dealer.
The compressor and the fan
switch off under this condition.
The compressor and the fan
switch off under this condition.
The compressor and the fan
switch off under this condition.
The compressor and the fan
switch off under this condition.
®
DryFix
Tabla de contenido
loading

Tabla de contenido