Figure 3. Basic Wiring
BLACK
LINE
LOAD
BLUE
WHITE
LINE
WHITE
LOAD
/STRIPE
PUMP MOTOR OR
CONTROL BOX
Startup
OTHER SOURCES OF FLOODING BEFORE STARTING UNIT.
1. Prime pump if necessary and adjust tank precharge to
manufacturer's recommendation for intended pressure
range. The factory Guardian CP
and 60 psi cut-out.
2. Turn on power and ensure Guardian CP display
illuminates, "88" will appear, then code revision
number, then "00". Display will blank momentarily and
the pump will start. If not, check installation.
3. The display will now read the current line pressure.
4. Allow the pump to reach the factory cut-off setting
of 60 psi. IF THE PUMP CANNOT REACH THIS
SETTING, DISCONNECT POWER AND SEE THE
TROUBLESHOOTING SECTION.
5. Check
for
leaks
before proceeding.
6. Proceed to the ADJUSTMENT section.
NOTE: During the first 30 seconds after start up, the pump
can be made to operate manually by depressing the 5
arrow for 6 seconds. This is useful for priming jet pumps.
Adjustment
NOTE: Differential pressure cannot exceed 55 psi or be
less than 10 psi. If display will not change, alter cut-in or
cut-out to within 55 psi.
1. Press and hold  until "LO" appears, then release.
This will determine the pressure at which the
pump activates.
2. When number appears, tap 5 or 6 to change
cut-in setting.
3. Press  again. When "HI" appears, tap 5 or 6 to
change cut-out setting. This will determine the pressure
at which the pump shuts off.
TYPICAL WIRING
CONNECTIONS
BEFORE CONTINUING, CHECK
FOR OPEN DRAIN VALVES OR
setting is 40 psi cut-in
®
and
repair
as
necessary
L1
L2
LINE IN
115/230 VAC
LINE IN
L1
L2
L3
TO MOTOR
NOTE: Press  a third time to display the last
Error Code in memory (see Error Code table).
If
no
errors
show "- -".
4. After approx. 10 seconds "Pr" will appear, indicating
the settings are programmed. Display will then revert to
line pressure.
NOTE: Settings will be stored until changed manually,
even if there is a power failure.
NOTE: If pump cannot reach cut-out setting within 5
minutes with no water running, lower the pressure settings
to fall within the pump's pressure capabilities.
NOTE: Pressing 5 6 together for 3 seconds will rotate
the screen 180 degrees for easier viewing.
Operation
The Guardian CP incorporates built-in diagnostic functions
to protect the system and alert the user or installer to
potential problems. If a fault is found, an error code will be
displayed, indicating that service may be necessary. Error
codes are listed in the Error Codes section.
Maintenance
A licensed professional should check the complete system,
including the Guardian CP, yearly and more frequently as
the system ages.
Warranty
Guardian CP Model DC2: Two (2) Year Limited Warranty
Unit contains no serviceable parts. Removal of main circuit
board cover will void warranty.
Visit www.amtrol.com for complete warranty details.
Y
B
R
TO
MOTOR
GUARDIAN CP
BLACK
BLUE
WHITE
WHITE/STRIPE
3-PHASE CONTROL BOX
FUSES
GUARDIAN CP
BLACK
BLUE
COIL
WHITE
WHITE/STRIPE
CONTACTS
have
occurred,
the
display
will