Battery Safety Instructions - Levenhuk Wezzer Air MC60 Guia Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 9
Levenhuk Wezzer Air MC60 Air Quality Monitor
EN
Caution! Please remember that mains voltage in most European countries is 220–240V. If you want to use your device in a country with a
different mains voltage standard, remember that use of a converter is absolutely necessary.
Charging the device
Connect the micro USB cable to the device. Then, with a DC adapter (not included) via a USB plug connect it to the AC power supply. Attention!
The device operates from the AC power supply, as the voltage of the computer's USB port is insufficient for the proper operation of the device.
Using
Press (1) for 3 seconds to turn the device on/off.
Settings
Press (1) twice. Press (2) or (3) to change the value, and then press (1) to continue.
The setting order: date > time > temperature unit (°C/°F) > alarm sound on/off > temperature offset.
History record
Press (2)/(3) to navigate the trend screen. The graph shows the last 5 CO2 data values every 10 minutes over the past 50 minutes.
CO2 scale
Air quality level
Good
normal outdoor air CO2 level
Ok
ventilation is recommended
Poor
is associated with such symptoms as
headache, sleepiness, poor attention,
increased heart rate, and nausea
Specifications
Operating CO2 range
Air humidity, units of measurement
Operating humidity range
Temperature, units of measurement
Operating temperature range
Power supply
Micro USB cable
The manufacturer reserves the right to make changes to the product range and specifications without prior notice.
Care and maintenance
Take the necessary precautions when using the device with children or others who have not read or who do not fully understand these
instructions. Make sure that the air flow channels at the back of the device are not blocked or covered. Do not try to disassemble the device
on your own for any reason. For repairs and cleaning of any kind, please contact your local specialized service center. Protect the device
from sudden impact and excessive mechanical force. Store the device in a dry cool place. Only use accessories and spare parts for this
device that comply with the technical specifications. Never attempt to operate a damaged device or a device with damaged electrical parts!
If a part of the device or battery is swallowed, seek medical attention immediately. Children should use the device under adult supervision
only.

Battery safety instructions

Always purchase the correct size and grade of battery most suitable for the intended use. Always replace the whole set of batteries at one
time; taking care not to mix old and new ones, or batteries of different types. Clean the battery contacts and also those of the device prior
to battery installation. Make sure the batteries are installed correctly with regard to polarity (+ and –). Remove batteries from equipment
that is not to be used for an extended period of time. Remove used batteries promptly. Never short-circuit batteries as this may lead to high
temperatures, leakage, or explosion. Never heat batteries in order to revive them. Do not disassemble batteries. Remember to switch off
devices after use. Keep batteries out of the reach of children, to avoid risk of ingestion, suffocation, or poisoning. Utilize used batteries as
prescribed by your country's laws.
Current CO2 value (ppm)
400–800
800–1200
1200–5000
400–5000ppm
% (RH)
20... 85%
°C, °F
–10... +50°C (+14... +122°F)
Li-ion battery (3000 mA∙h), DC adapter 5V 1000mA (not included)
3m, included
3
Indication
Green
Yellow
Red