Ecler CA120HZ Manual De Usuario página 62

Ocultar thumbs Ver también para CA120HZ:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TYPE
PARAM1
PARAM2
INC/DEC
PRESET_NUMBER
<Count>
IN_VOL
<Input=I1:I6>
IN_BASS
<Input=I1:I6>
IN_MID
<Input=I1:I6>
IN_TREBLE
<Input=I1:I6>
XLEVEL
<Input=I1:I6>
ZONE_VOL
<Zone=ZA:ZD>
GEQ_GAIN
<Zone=ZA:ZD>
PARAM3
PARAM4
<Count>
<Count>
<Count>
<Count>
<Zone=ZA:ZD>
<Count>
<Count>
<Band=B1:B10>
<Count>
62
DESCRIPCIÓN
INCrements / DECrements the current active PRESET number
Increments / decrements a certain INPUT's current VOLUME. The increment
applied is defined by the Count parameter (dBx10)
Increments / decrements a certain INPUT's current BASS tone LEVEL. The
increment applied is defined by the Count parameter (dBx10)
Increments / decrements a certain INPUT's current MIDDLE tone LEVEL. The
increment applied is defined by the Count parameter (dBx10)
Increments / decrements a certain INPUT's current TREBLE tone LEVEL. The
increment applied is defined by the Count parameter (dBx10)
Increments / decrements a certain CROSSPOINT current VOLUME (matrix level
sent from one input to one output). The increment applied is defined by the
Count parameter (dBx10)
Increments / decrements a certain output ZONE current VOLUME. The increment
applied is defined by the Count parameter (dBx10)
Increments / decrements, in a certain output ZONE, the current GAIN for a certain
GRAPHICAL EQUALIZER band. The increment applied is defined by the Count
parameter (dBx10)