CLEANING AND MAINTENANCE

A blocked filter will impair the cooling and heating performance
of the unit significantly.
The filter must be cleaned periodically to ensure that it does
not become clogged with dust and other particles. The state of
the filter can be ascertained from its appearance. If it appears
dirty or clogged then it should be cleaned.
WARNING
Airborne particles can pose a health risk, particularly to
young children and the elderly. Ensure that filters are cleaned
in a safe and well ventilated area.
To Clean the Filter
The filter should be cleaned every four weeks or more when in
use. Prolonged use, higher concentrations of airborne particles
and various other factors may result in the filters needing to be
cleaned more often.
1.
Remove the filters by pushing the tabs to release. (Fig. 29)

TROUBLESHOOTING

Problem
Cause
Rooftop air
conditioner
Freeze sensor has tripped.
constantly switches
itself off
The rooftop air conditioner is
not set to cooling.
The set temperature is too high.
The evaporator fan is damaged.
Not cooling well
The condenser fan is damaged.
The air intake grilles are
blocked or obstructed.
The blower is defective.
The condensation water
drainage openings are clogged
Water enters the
up.
vehicle
The seals are damaged.
No supply voltage connected.
Rooftop air
The voltage is too low.
conditioner does not
switch on
Fuse blown or circuit protector
tripped.
2. The filter can be washed with warm soapy water. Care
must be taken to avoid ripping the fabric.
3. Replace the filters and decoration plate, by reversing the
above process.
NOTE: The filter must be completely dry before re-
installation.
To Replace the Filter
Filter changes should be carried out depending on the amount
of use, it is recommended to change at least every 12 months.
Never operate the air conditioning system without a filter, since
this can decrease performance and indoor air quality.
Replacement return air filters can be ordered directly from
Furrion.
Remedy
Outer temperature is too low or all air nozzles are closed.
Set the rooftop air conditioner to cooling.
Select a lower temperature.
Contact an authorized service agent or Furrion (see the detail contact info at the back page of this
manual).
Contact an authorized service agent or Furrion (see the detail contact info at the back page of this
manual).
Remove any leaves and other dirt from the ventilation grilles of the rooftop air conditioner.
Contact an authorized service agent or Furrion (see the detail contact info at the back page of this
manual).
Clean the drainage openings for condensation water.
Contact an authorized service agent or Furrion (see the detail contact info at the back page of this
manual).
Check the power supply.
Contact an authorized service agent or Furrion (see the detail contact info at the back page of this
manual).
Check the electrical fuse of the power supply.