OUTDOOR UNIT INSTALLATION INSTRUCTIONS

ATTENTION: The following procedure should be followed before connecting the pipes and electrical wiring.

INSTALLATION OF THE OUTDOOR UNIT

Choose the location of the installation according to the struc-
ture of the dwelling.
Determine the best position on the wall or floor and allow
ample space for future maintenance.
The outdoor unit must be installed on a solid wall or floor stand
and secured.
Fix the wall bracket with screws and plugs suitable for this
type of wall installation or install a suitable floor bracket.
The outdoor unit must be placed at least 3 cm above the floor
to allow for the installation of the drainage fitting.
INSTALLATION OF THE CONDENSATE PIPE ON THE
OUTDOOR UNIT
Condensed water and frost that forms on the outdoor unit in
heating mode can be discharged through a condensate pipe.
1. Attach the condensate pipe fitting as shown.
2. Connect the condensate hose to the fitting.
Ensure that the water drains into a suitable area.
11
Drainage fitting for
condensate pipe
EN
Condensate
pipe