welding. Insert the cartridge through the upper part of the attachment so that its end is under the attachment's skid. The skid of
the heated attachment will melt the cartridge and the air from the nozzle will melt the edges of the bonded objects. The plastic
cartridge should be moved manually as the attachment's skid moves across the bonded material. The temperature and airfl ow
speed depend on the type of plastic and the bond surface. It is recommended to carry out test bonding on waste material. It is
recommended to use a cartridge made of the same material as the elements to be bonded.
WARNING!
When welding plastics, do not exceed 300 - 350
O
C
The time of continuous operation during welding of plastics cannot exceed 10 minutes.
Failure to comply with the above recommendations may result in heat gun damage due to overheating.
Drying
The heat gun also enables quick drying of binders and car body fi llers, drying of paint samples, building connections before the
application of soundproofi ng - sealing materials, drying of joints and slots in boatbuilding, drying of polyester putty.
MAINTENANCE AND OVERHAUL
ATTENTION! Before any adjustment, technical service or maintenance operations unplug the tool. Once the operations have been
fi nished, the technical conditions of the tool must be assessed by means of external evaluation and inspection of the following
elements: body and handle, conductor with a plug and defl ection, functioning of the electric switch, patency of ventilation slots,
sparking of brushes, noise level of functioning of bearings and gears, start-up and smoothness of operation. During the guarantee
period, the user cannot dismantle the electric tools or change any sub-assemblies or elements, since it will cancel any guarantee
rights. All irregularities detected at overhaul or during functioning of the tools are a signal to have the tool repaired at a service
shop. Once the functioning has been concluded, the casing, ventilation slots, switches, additional handle and protections must be
cleansed with a stream of air (at a pressure not exceeding 0.3 MPa), with a brush or a cloth without any chemical substances or
cleaning liquids. Tools and handles must be cleansed with a clean cloth.