3. Remove the mounting template and drill holes in the wall.
4. Insert the plugs into the holes made.
5. Screw the four metal anchoring pieces to the wall with the 6.3 x 50 mm screws.
6. Insert the product into the metal wall anchoring parts and fasten with the 2.9 x 9.5 mm
grub screw.
Nº.
ITEM
1
10 mm rawl plug
2
Metal fastener
3
Screw Ø 2.9 x 9.5 mm
4
Screw Ø 6.3 x 50 mm
5
Product
INSTALLATION AND SAFETY PRECAUTIONS (UNE-EN 60335 REGULA-
TION)
Before starting the heater, read the "Installation and Safety Precautions" carefully to ensure
proper operation of the heater.

PRECAUTIONS FOR INSTALLATION

The towel rail is designed for domestic or residential use. We recommend that the towel
rail is installed by a distributor or an approved professional. Make sure that the heater is
correctly connected to 220V-230V.
This appliance has been designed for installation in a residential room. The installation
must be carried out in accordance with the standards in force in the country of
installation (NFC 15100 for France).
The towel rail must be directly connected to the mains after the omnipolar cut-off device
with a contact opening distance of at least 3 mm without any intermediate switch
(clock, mechanical and static relay, room thermostat, etc.).
The connection to the mains is made with a 3-wire cable (Brown = Phase, Blue =
Neutral, Black = Control wire) via a connection box. In wet rooms such as kitchens and
bathrooms, the connection box must be installed at least 25 cm from the floor. The
TORINO OVAL WI-FI ELECTRIC TOWEL RAIL
5
3
2
1
4