Simu T3.5EBHZ DC Manual De Instrucciones página 12

Ocultar thumbs Ver también para T3.5EBHZ DC:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
B
1
1- Position the motor on the Up end limit by using the buttons "UP" or "DOWN".
2- To memorize the UP end limit position, press simultaneously the buttons "STOP" and "DOWN". The motor
will run automatically in the down direction.
3- Press the "STOP" button to immobilize the motor (Optional).
4- Press 2 seconds the "STOP" button to validate the setting. The motor will run for half a second in one
direction, then in the other direction. The operation is completed. Go to step §4.
C
1
1- Position the motor on the Down end limit by using the buttons "UP" or "DOWN".
2- To memorize the Down end limit position, press simultaneously the buttons "STOP" and "UP". The motor
will run automatically in the UP direction.
3- Press the "STOP" button to immobilize the motor (Optional).
4- Press 2 seconds the "STOP" button to validate the setting. The motor will run for 0.5 second in one
direction, then in the other. The operation is completed. Go to step §4.
1
D
1- Position the motor on the Down end limit by using the buttons "DOWN" or "UP".
2- To memorize the Down end limit position, press simultaneously the buttons "STOP" and "UP". The motor
will run automatically in the Up direction.
3- When the motor arrives on the Up End limit, press the button "STOP".
4- If necessary adjust the position with the button "UP" or "DOWN".
5- To memorize the Up end limit position, press simultaneously the buttons "STOP" and "DOWN". The
motor will run automatically in the Down direction.
6- Press 2 seconds the "STOP" button to validate the setting. The motor will stop, and will run for 0.5 second
in one direction, then in the other. The operation is completed. Go to step §4.
If you do not want to use this transmitter as the individual control:
- cut the power supply (2 seconds minimum).
- repeat the operation 3.1* with a new transmitter and then go to step §4.
* In this case, the motor will run for 0,5 second in both directions, that means the limits setting is already done.
PROGRAMMING THE FIRST INDIVIDUAL CONTROL POINT
4
This operation can only be performed from the transmitter that was used for operation 3.1.
- Press the transmitter "PROG" key for approximately one
second. The motor will run for 0.5 second in one direction
and then in the other.
i
- Your transmitter is now programmed to control the motor in stable mode. Go to step §5.
4/8
EN
2
2
2
3
3
3
4
5
1
PROG 1s
4
2 s
4
2 s
6
2 s
>>
Tabla de contenido
loading

Tabla de contenido