Turn the device off.
Pull on the water tank and slide it out of the body of the dehumidifier.
Empty the water in the tank.
Clean the inside and the outside of the tank.
Reinstall the empty tank. Fig. 3.
Press the power button to resume operating.
If the Full tank light does not turn off, check that the float is correctly in place.
Continuous draining: Use gravity to drain condensate water by attaching a drain hose.
Connect the drain hose to the unit. Condensate water can flow into a bucket or drain by
gravity.
Set the unit in a horizontal surface and stable position.
Switch off the unit before operating.
Move the plug away from the water outlet opening and keep it in safe area.
Fig. 4.
Securely and properly connect the drain hose and make sure it is not kinked and clear of
obstruction.
Place the outlet of hose over a drain or bucket and ensure that water could freely flow out of
the unit.
Do not submerge the end of hose into water; otherwise it can cause air lock in the hose.
Fig. 5.
To avoid water spillage:
As the negative pressure of condensate drain container is large, tilt the drain hose downward
toward the floor. Make sure the degree of inclination exceeds 20º.
Straighten the hose.
Cleaning the filter
We recommend doing this every two weeks.
The device's capacity may be reduced if the filter is clogged. Dust collects on the filter and
restricts the airflow. The restricted airflow reduces the efficiency of the system and if it
becomes blocked it can cause damage to the unit.
The air filter is removable for easy cleaning. Do not operate the unit without an air filter, or
the evaporator may be contaminated.
Remove the filter frame and take off the filter. Fig. 6.
Soak the filter in warm water at about 40 ºC. Rinse gently with a neutral detergent.
Use the vacuum cleaner's brush to gently remove dust from the screen.
Fig. 7.
Replace the filter.
Fig. 8.
50
BIGDRY 7000 MASTER CONNECTED

7. TROUBLESHOOTING

Problem
Possible cause
The unit doesn't
No power supply
operate
The tank is full or not
installed properly
Is the temperature of the
room above 35 ºC or below
5 ºC?
The dehumidifying
Is the filter clogged?
function doesn't work
Is the intake duct or
discharge duct obstructed?
No air is discharged
Is the filter clogged?
The device produces
Is the unit tilted or
strange noises when
unsteady?
operating
Is the filter clogged?
Errors
E2
Humidity sensor error
LO
Environmental humidity is below 20 %
HI
Environmental humidity is above 90 %
Low temperature protection, the room
CL
temperature <5ºC
High temperature protection, the room
CH
temperature >35ºC
ENGLISH
Solution
Plug the power cord into the
outlet.
Empty the water in the tank and
then reinstall the tank.
The protection device is
activated and the unit
cannot operate.
Clean the filter as described in
this manual.
Remove the obstruction from the
discharge duct or intake duct.
Clean the filter as described in
this manual.
Move the unit to a stable, sturdy
location.
Clean the filter as described in
this manual.
Contact the Technical Support
Service of Cecotec
The dehumidifier shuts down
for self- protection