Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Page 4
Extend the length of the secondary side cable
The power supply is delivered with a 5-meter cable on both the primary and
secondary sides, (see the illustration). The primary cable must be fitted with
the appropriate country-specific plug.
Cables may be shortened or lengthened to fit the application. If the
secondary cable needs to be more than 5 meters (the original cable length)
or if more than one product is to be connected, follow these recommended
instructions:
Cut the secondary cable to a maximum length of 25cm. This length will
minimize the voltage drop in the shared part of the cable.
Split the secondary cable and connect it to the cable(s) that will run to your
unit(s) - one cable for each connected product.
• Use an appropriate
splitter/connector (not
included).
• You may need to sub-
stitute the power
cable which was sup-
plied with your Axis
product with a new
cable of minimum
18AWG (not included).
• Place the splitter device in a protective, weather-tight conduit.

Important!

• The total maximum current consumption for all connected products must not exceed the
PS12 maximum output current limit (4.5A).
• Use cables and conduits suitable for the installation and that are in compliance with the
IP67 rating.
• Note that if your installation is to be vandal resistant, you will also need to make sure all
cable conduits are vandal resistant.
AXIS PS12 Outdoor Power Supply
Splitter/Connector
AXIS PS 12
Extended cable
Max 25cm
Extended cable
Extended cable
Unit 1
Unit 2
Unit 3
Tabla de contenido
loading

Tabla de contenido