The evaporator in the dehumidifier may defrost automatically if it is operated in
the room temperature less than 18°C. The defrosting process may start up and operate for some time
(about 5 minutes) automatically every 25 minutes or even
longer.-During the defrosting operation, the dehumidification function and
air purification function may intermit. Please don't turn off the switch or pull
out the power plug of the dehumidifier during the defrosting operation.
This dehumidifier can't be applicable to keep extreme low temperature.
The purpose of the dehumidifier is to pump off the unpleasant high humidity
Please note if the ROOM temperature is less than 24℃, the unit will start defrost function!
12-18°C: 25minute dehumidify then 5minute defrost, cycle;
5-12°C: 20minute dehumidify then 5minute defrost, cycle; 5-12°C
≤5°C: unit protection, compressor of, fan of. All operation mode cannot be activated except air circulation
Touble Shooting
temp. sensor erro
working temp. is low, it is normal
working temp. is high, it is normal
unit is in defrost mode
Defrosting operation
in daily life and dry the wet things.
But it can't be used to keep extreme low temperature
Defrost procedure
≥24°C: no defrost
18-23°C 2hours dehumidify then 5minute defrost, cycle;
water full
phenomenon
phenomenon
mode
.