EN
There are no stem
released when use
steam function.
Display shows Error
Code "E01"
Display shows Error
Code "E02"
Display shows Error
Code "E03"
38
The suction pipe in the water tank
is upturned.
Steam may not be visible.
The nozzle blockage.
The water pump doesn't work.
There is an open circuit in NTC
sensor.
There is an short circuit in NTC
sensor.
The PCB communication error.
Place the suction pipe at the
bottom of the tank.
Confirm whether the water in the
water tank is significantly reduced
by using the cleaning function to
work for a few minutes.
Remove the nozzle for cleaning,
and ensure that small holes on the
nozzle are unblocked.
Please contact after-sales service.
It may be loose or disconnected,
please contact professional after-
sales service.
Maybe the NTC sensor is
damaged, please contact
professional after-sales service.
Maybe the wire installation
wrong or broken, please contact
professional after-sales service.