→ Forced start:
A few safety mechanisms are deactivated for this starting procedure. Please exercise particular care for this
reason. Never reverse the polarity.
1.
Check the battery. It should be a 12 V battery with under 6 V of power. Never connect the jump starter
to a vehicle with an active ignition. Only activate the ignition after connection.
2.
First connect the black terminal to the earth terminal on the vehicle body.
3.
Then connect the red terminal to the positive terminal on the battery.
4.
Press the "Start/Stop" button for 7 seconds until the blue LED illuminates and then start the vehicle. If
starting is unsuccessful at the first attempt, wait 3 minutes for the next attempt to avoid stress to the
system.
5.
Switch off the jump starter immediately following starting.
6.
Disconnect the connection and remove the device.
Use of "Memory Saver" storage supply:
Please do not use this function to start the vehicle. A few safety mechanisms are deactivated for this starting
procedure. Particular care should be exercised for this reason. Never reverse polarity.
1.
Please check the vehicle system. It should be a 12 V-based system.
2.
First connect the black terminal to the earth terminal on the vehicle body.
3.
Then connect the red terminal to the positive terminal on the battery.
4.
Press the "Start/Stop" button for 5 seconds. The blue and yellow LED are then activated and "MEMO"
appears on the display. The device is now activated as a power source.
5.
Press the "Start/Stop" when the work is concluded to deactivate the device.
Error messages:
The Error LED illuminates and an error message with the following meaning appears on the display:
Display message
Err-1
Err-2
Err-3
Err-4
Err-5
Err-6
Err-7
Disposal:
Do not dispose of electrical appliances and batteries/rechargeable batteries in household waste.
Old electrical and electronic devices and batteries/rechargeable batteries must be collected separately and
recycled in an environmentally friendly manner. Illegal disposal of the product is a breach of the law on
disposal of hazardous waste and will be penalised.
EC Declaration of Conformity:
We declare, on our own responsibility, that the product described complies with all relevant
provisions of the following directives:
• Directive on electromagnetic compatibility (EMV) 2014/30/EU
• Low voltage directive (LVD) 2014/35/EU
• Directive on restriction of the use of certain hazardous substances in electrical and electronic equipment
(RoHS) 2011/65/EU
JM-Products
Hammerbrookstr. 97
20097 Hamburg
Deutschland
Tel.: + 49 (0) 40 2 37 21-0
www.jmproducts.eu
Cause
Polarity reversal / Short circuit / Battery damaged / Device not connected.
Incorrect voltage range (e.g. 24 V or 6 V battery).
Jump starter overheated. High temperature of internal lithium battery.
Internal lithium battery flat.
9 V auxiliary battery flat.
Overloading during starting attempt.
Overloading during "Memory Saver" storage provision.