COMPACT 1.4
VEHICLES WITH ORIGINAL POWER SUPPLY CABLING - Electrical layout
Take care not to invert polarities when connecting the unit to the power supply. If this were to happen,
the plate would not come on and the unit would not work.
Centrifugal
blower
2,6 Amp.
Az
Blue
N
Black
R
Red
V
Green
B
White
A
Yellow
Na Orange
M
Brown
Compressor
electronic
module
IMPORTANT NOTE!
Electronic
control
2 Compressor
Air conditioning for vehicles
Comsuption 30 mAmp.
Compressor
electronic
13
Return air
sensor
NTC 15KΩ a 25º
Original wiring
Condenser
fan
2,9 Amp.
PWM.
module
1 Compressor