Intesis IntesisBox DK-AC-ENO-1 Manual De Usuario página 23

Interfaz enocean para aire acondicionado daikin. compatible con todos los modelos de la gama doméstica
Tabla de contenido
®
IntesisBox
ORG = 07 (4 BS)
FUNC = 20 HVAC Components
TYPE = 11
Generic HVAC interface – Error control: AC Error code, Error states and disablements
EEP for Generic HVAC interface – Functions: Mode, vane position, fan speed, sensors and on/off: With this EEP plus
the already existing EEP 07-10-03 and 07-20-10 all the information of AC indoor unit can be sent and received
allowing a much easier and complete control of these units.
Teach-In
The teach-in telegram has the same structure as a normal 4BS telegram.
see. Standardization EnOcean Equipment Profiles (EEP) V2.0
The actuator expected after successful teach-in a 4BS teach-in acknowledge
and use the following structure.
DB_3:
Function, same as teach-in telegram heating valve = 20
DB_2:
type, same as teach-in telegram actuator = 01
DB_1:
Intesis Software ID:19
DB_0.BIT_7:
LRN TYPE = 0b1 (type 1 with profile, manufacturer Id)
DB_0.BIT_6:
EEP result; EEP supported = 0b1, EEP not supported = 0b0
DB_0.BIT_5:
LRN result; ID stored = 0b1, ID deleted (not stored ) = 0b0
DB_0.BIT_4:
TA= teach in answer = 0b1
DB_0.BIT_3:
LRN Learn button
DB_0.BIT_2:
not used
DB_0.BIT_1:
not used
DB_0.BIT_0:
not used
© Intesis Software S.L. – Todos los derechos reservados
La información de este documente puede cambiar sin previo aviso.
IntesisBox es una marca registrada de Intesis Software SL
DK-AC-ENO-1/1C
0b0 Teach-in telegram
0b1 Data telegram
v.1
Manual de Usuario
URL
http://www.intesis.com
email
tel
+34 938047134
rev.5
EEP: 07-20-11
23 / 30
Tabla de contenido
loading

Este manual también es adecuado para:

Intesisbox dk-ac-eno-1c

Tabla de contenido