Never fit the carbon monoxide alarm on the ceiling !!!
VI. Installation instructions
Install the unit where it's easy for the user to test and operate. For wall mounting,
the height of installation position should be more than 1.5m. The unit should be
at least 0.3m from the ceiling and 1.5m away from a corner, wall side or large
furniture. Follow below installation steps :
-
Remove the mounting plate
and line it with the wall in the
position that you have chosen
for installation. Mark the holes
with a pencil dot.
-
Make two holes (6mm diameter,
40mm depth) on the marked
spots.
-
Remove the Buckle PIN from the
mounting plate.
-
Insert the two plastic anchors
into the drilled holes. Secure
the mounting plate to the wall
upwards.
-
After making sure the mounting
plate is secured to the wall,
power on the detector
according to previous intruction
and test it. If the test result is
normal, then slide the alarm
down over the mounting plate
until it snaps into place.
-
Insert the PIN in to the buckle
holder to lock the mounting
plate on the device.
8
EN
Note : The detector cannot snap into place until the batteries are installed cor-
rectly. Please don't force to install in avoidance of damage.
In order to ensure the product is correctly installed and used, it should be
installed strictly according to this user manual or be installed by qualified
professionals.
8. Maintenance
I. Alarm by other gases
The following gases make cause false alarm or damage the sensor:
Methane, propane, isobutane, ethylene, ethanol, alcohol, isopropanol, benzene,
toluene, ethyl acetate, hydrogen, hydrogen sulfide and sulfur dioxide. Almost
all the Aerosol spray, alcoholica, paint, thinner, solvent, binder, hair spray, after-
shave,perfume, car exhaust (cold start) and some cleaning detergents.
When the product is exposed to the gases mentioned above, it may make false
alarms or be damaged permanently. When alarms are activated and you smell
irritating gas, it may be false alarm because CO is colorless and odorless.
Put the product in clean air, if it's still in alarm condition 30 minutes later, then
that means the product has been polluted. You should place the power-off unit
in clean air for a long time. If the product can't recover 24 hours later, then it
means the sensor has been damaged. Please don't use the product any more.
Warning:
When the alarm is damaged permanently, please stop using it. Don't repair it
jourself or send to the service point that is not authorized by the manufacturer.
II. Cleaning and maintenance
The product must be kept clean when used, or its performance will be influ-
enced and even may cause damage to the alarm. It shall be cleaned and tested
once a month in the following way :
-
Remove dust with vacuum cleaner.
-
Rub the surface with wet soft cloth which has been wringed out.
-
Press the TEST button and make sure the detector woks properly, then
reinstall it to use. Don't clean the alarm with chemical like alcohol, petrol,
cleanser, etc., or it may cause damage to the alarm.
Important:
Clean the product once a month. Don't clean the alarm with chemical cleanser.