Fermax AC-MAX Manual De Instalador página 4

Ocultar thumbs Ver también para AC-MAX:
Idiomas disponibles

Idiomas disponibles

Cod. 970215
V06_22
Notes:
• 5226 is electrical interface and it does not require any configuration.
• The interface is equipped with plastic bracket for the installation of device on DIN35 rail.
• 5226 can be applied in various cases the connection diagram is similar to the fig. 2.
• The interface is dedicated to operation with single Wiegand reader. Each Wiegand terminal connected to
controller's inputs must be equipped with own 5226 interface.
• 5226 can be supplied from TML+/TML- lines of controller or expander, from AUX+/AUX- lines of controller
of expander and from own power supply unit. If devices are not supplied from the same power supply then
their GND terminals must be connected with any wire.
T
ECHNICAL DATA
Table 2. Specification
Supply voltage
Current consumption (average)
Inputs
Distances
IP Code
Environmental class (according to EN 50133-1)
Dimensions W x S x G
Weight
Certificates
CE DECLARATION OF CONFORMITY
Hereby, FERMAX ELECTRONICA, S.A.U., declares that this INTERFACE DATA 5226, is in compliance with
the essential requirements of Directive RED 2014/53/UE and Directive RoHS 2011/65/UE. See website
www.fermax.com. FERMAX Avd. Tres Cruces, 133, 46017 Valencia, Spain.
https://www.fermax.com/intl/en/pro/documents/technical-documentation/DT-13-declarations-of-conformity.html
WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT – DI
The device you have purchased is identified under Directive 2012/19/EU on waste electrical
and electronic equipment.
This symbol placed on a product or packaging indicates that the product should not be
disposed of with other wastes as this may have a negative impact on the environment and
health. The user is obliged to deliver equipment to the designated collection points of electric
and electronic waste. For detailed information on recycling, contact your local authorities,
waste disposal company or point of purchase. Separate collection and recycling of this type of
waste contributes to the protection of the natural resources and is safe to health and the
environment. Weight of the equipment is specified in the document.
Nominal 12VDC, min./max. range 10-15VDC
10mA
Two (D0 IN, D1 IN) inputs with 3.5V triggering level.
Two (D0 OUT, D1 OUT) open collector outputs with 5mA max
load in low state
Up to 150 m between interface and Wiegand reader
The distance between interface and controller should be as
short as possible. It is recommended to install the interface
inside metal box of controller.
IP00
Class I, indoor general conditions, temperature: +5°C to
+40°C, relative humidity: 10 to 95% (no condensation)
80 x 17 x 35 mm
~20g
CE
loading

Este manual también es adecuado para:

5226