Starting The Engine - Raven GEN 4000 Manual Del Propietário

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

STARTING THE ENGINE

Recoil Start(GEN 4000)
1.
Unplug everything from the outputs.
2.
Turn the fuel valve to the "ON" position.
3.
Turn the AC circuit breaker to the "OFF" position.
4.
Turn the choke lever to the "CLOSE" position.
NOTICE
Don't close the choke when starting the engine in a warm state.
5. Turn the generator switch to the "ON" position.
6. Pull the starter grip until resistance is felt, and then pull it out briskly.
7. Turn the choke lever to the "OPEN" position after the engine is warm.
8. Don't use plugged-in electric appliances before setting the circuit
breaker to the "ON" position.
Electric Start (GEN 6500E Units)
1.
Turn on the generator switch to the "on" position.
2.
Push and hold the electric start switch down until the engine starts.
3.
Turn the choke lever to the "open" position as engine warms up.
4.
Don't use electrical devices or appliances that are plugged in before
setting the circuit breaker to the "on" position.
5.
Turn the generator switch to the electric starting position.
6.
After starting the engine, immediately release the generator switch so
the generator switch can automatically return to open position.
7.
Turn the choke lever to the "OPEN" position after the engine is warm.
NOTICE
Turn the generator switch to the electric starting position and hold for
no longer than 5 seconds, or it will cause damage to the starting motor.
If starting fails, release the switch and wait 10 seconds before
operating it again.
If the speed of the starting motor drops quickly after running for a
period of time, the battery should be recharged.