Spare Parts
Only use original Kärcher spare parts. You
will find a list of spare parts at the end of this
document.
Troubleshooting
You can rectify minor faults yourself with the
help of the following overview.
If in doubt, please consult the authorized
customer service.
Risk of injury
Always switch off the appliance and pull out
the mains plug before care and maintenance
work.
Warning
Repair works may only be performed by the
authorized customer service.
Machine does not start
" Check whether the voltage indicated on
the type plate corresponds to the voltage
of the socket.
" Check the power cord for damage.
Pressure does not build up in the appli-
ance
" Check the setting at the spray lance.
" Appliance ventilation: Switch on the ap-
pliance without connection the HP hose
and run it until the water discharging
from the HP outlet is free of bubbles.
Switch off appliance and reconnect
spray lance.
" Clean the filter in the water supply con-
nection: This can be easily removed us-
ing flat-nose pliers.
" Check all supply lines to the HP pump for
leaks or blockages.
Strong pressure fluctuations
" Clean the high-pressure nozzle: Re-
move dirt and debris from the nozzle
bore with a needle and rinse through with
water towards the front.
" Check the volume of incoming water.
HP pump leaking
All manuals and user guides at all-guides.com
" Slight leakage from the HP pump is nor-
No detergent infeed
" Select the low-pressure setting for the
" Clean the filter of the detergent suction
" Check the DT suction hose for kinks.
Power connection
Voltage (1~50 Hz)
Connection output
Mains fuse (slow-blow)
Protective class
Water connection
Max. feed temperature
Min. feed volume
Feed pressure,
Performance data
Working pressure
Max. permissible pressure
Water flow rate
Detergent flow rate
Recoil force of handgun
Hand-arm vibration
(ISO 5349)
Sound pressure level
Lpa (EN60704-1)
Sound power level
Lwa (2000/14/EG)
Dimensions
Depth
Width
Height
Weight
mal. If the leakage increases contact the
authorized customer service.
spray lance.
hose.
Specifications
230 V
1,9 kW
10 A
I
40 °C
10 l/min
0,2 - 1,2 MPa
12 MPa
13 MPa
6,7 l/min
0,3 l/min
18 N
2,2 m/s
2
77 dB(A)
92 dB(A)
420 mm
445 mm
590 - 930 mm
19,5 kg
15