Operating Instructions
Air Tool Set-Up
NOTE: It is not recommended to install
a quick coupler between the tool and
the whip hose.
For proper performance and more con-
venience, use a 3/8" I.D. hose. Hoses
longer than 50 feet should have a 1/2"
I.D.
Liquid Flow
Control Valve
Spray
Nozzle
Trigger
1/4" NPT Male
Air Inlet
Figure 1 - Cleaning Gun Features
Troubleshooting Chart
Symptom
Possible Cause(s)
1. Solution buildup
Tool not
siphoning
solution
2. Corrosion
properly
3. Low air pressure
4. Air hose leaks
5. Pressure drops
6. Liquid flow control
valve shut-off
Operation
NOTE: The use of a lubricator is NOT
recommended with this tool.
WARNING
!
exposure to vibration, work in awk-
ward positions and repetitive work
motions can cause injury to hands and
arms. Stop using any tool if discomfort,
numbness, tingling or pain occur, and
consult a physician.
1. Connect the solution hose to the
barb fitting.
2. Place material strainer end of hose
Barb
into the solution being sprayed.
Fitting
3. Connect to air supply.
4. Pull the trigger and allow approxi-
mately 5 seconds for the solution to
reach the spray nozzle. Release the
trigger to stop the flow.
5. Adjust liquid flow control valve to
obtain desired solution flow.
Corrective Action
1. Remove by flushing with warm water
2. Disconnect hose from tool and add two drops of mineral spirits through the
barb fitting on the tool after each use (See Figure 1)
3. Adjust the compressor regulator to tool maximum (90 psi) while the tool is
blowing air
4. Tighten and seal hose fittings if leaks are found
5a. Be sure the hose is the proper size. Long hoses or tools using large volumes of
air may require a hose with an I.D. of 1/2" or larger depending on the total
length of the hose
5b. Do not use a multiple number of hoses connected together with quick connect
fittings. This causes additional pressure drops and reduces the tool power. Di-
rectly connect the hoses together
6. Adjust liquid flow control valve to desired flow
STORAGE
The cleaning gun must be thoroughly
flushed with water before storing.
Refer to cleaning solution Material
Do not misuse this
Safety Data Sheet (MSDS)
product. Excessive
TECHNICAL SERVICE
For information regarding the opera-
tion or repair of this product, please
call 1-800-543-6400.
2
HDT132