12. Apply clamp over outside cable and
tighten. Trim excess clamp.
13. Connect lead wires accordingly.
14. Re-assemble the rear case.
B. Front-End Repair
1. Disassemble the front handle halves to expose the front connector assembly and pull
the assembly from the front handle case.
2. Cut the Cablehoz
®
3. Use replacement connector assembly,
Part No. MS102-RK (Stock No. 2060-
2132) on 250 Amp Tweco
Guns.
4. Measure back 2-1/2" (63,5 mm) from the end of the Cablehoz and cut away the outer
jacket of the cable, being careful not to cut the copper strands and or lead wires.
5. Pull the copper strands and lead
wires away from the inner core tube
that is exposed and cut away leaving
approximately ¼" (6,35 mm) past the
end of the end of the Cablehoz.
6. Cut the copper strands to a length of ¾"
(19,05 mm) while leaving the wire leads
intact.